dc.creatorPaz Filgueira, Clemente
dc.creatorColombo, Elisa Margarita
dc.date.accessioned2019-11-27T20:38:20Z
dc.date.accessioned2022-10-15T12:35:59Z
dc.date.available2019-11-27T20:38:20Z
dc.date.available2022-10-15T12:35:59Z
dc.date.created2019-11-27T20:38:20Z
dc.date.issued2018-07
dc.identifierPaz Filgueira, Clemente; Colombo, Elisa Margarita; Quantifying the effect of straylight on photopic contrast sensitivity; Optical Society of America; Journal of the Optical Society of America A; 35; 7; 7-2018; 1124-1130
dc.identifier1084-7529
dc.identifierhttp://hdl.handle.net/11336/90722
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4386704
dc.description.abstractThe visual performance of a reference group (RG) using diffuser filters was compared to a cataract-diagnosed group (CatG). Measurements of straylight (SL) parameter, photopic contrast sensitivity (CS), and visual acuity (VA) were carried out in both groups. Before the analysis, the performance of the instruments used for this purpose was tested. The RG was comprised of three healthy, young eyes (25–30 years old) while 59 subjects (aged 50–80 years old) with lens opacities were recruited for the CatG. Six diffuser conditions were tested in the RG. To discriminate between light scattering levels, SL measurements proved to be most sensitive, VA did not discriminate at all, while CS showed intermediate sensitivity. VA was not correlated with SL, while the correlation between CS and SL was significant (p < 0.05) in both groups. Since the correlation in the RG was particularly strong, parameters of a linear regression model are presented. The behavior of CS as a function of SL was comparable to some extent between RG and CatG.
dc.languageeng
dc.publisherOptical Society of America
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/josaa/abstract.cfm?uri=josaa-35-7-1124
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1364/JOSAA.35.001124
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectContrast sensitivity
dc.subjectForward scattering
dc.subjectStraylight
dc.subjectVisual acuity
dc.subjectPsychophysics
dc.subjectVisual optics
dc.subjectOpthalmic appliances
dc.titleQuantifying the effect of straylight on photopic contrast sensitivity
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución