dc.creatorRiveras, Mauricio
dc.creatorRavera, Emiliano Pablo
dc.creatorShaheen, Aliah
dc.creatorEwins, David
dc.creatorCatalfamo Formento, Paola Andrea Lucia
dc.date.accessioned2021-10-06T18:30:15Z
dc.date.accessioned2022-10-15T12:15:40Z
dc.date.available2021-10-06T18:30:15Z
dc.date.available2022-10-15T12:15:40Z
dc.date.created2021-10-06T18:30:15Z
dc.date.issued2020-02
dc.identifierRiveras, Mauricio; Ravera, Emiliano Pablo; Shaheen, Aliah; Ewins, David; Catalfamo Formento, Paola Andrea Lucia; Spatio temporal parameters and symmetry in subjects ascending and descending a ramp, using three different prosthetic feet; Korean Society of Mechanical Engineers; Journal of Mechanical Science and Technology; 34; 2; 2-2020; 955-961
dc.identifier1738-494X
dc.identifierhttp://hdl.handle.net/11336/142925
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4384860
dc.description.abstractThis study aimed at evaluating spatiotemporal parameters (STP) and symmetry index (SI), commonly used for evaluating amputee gait for routine clinical use, in individuals with unilateral transtibial amputations wearing energy storage and return (ESAR) feet with fixed ankles, prosthetic feet with adaptive ankles (PFAA) and prosthetic feet with microcontrolled adaptive ankles (PFAA-MC) in ramp ascent and descent. Thirteen individuals with transtibial amputations walked up and down a ramp. The STPs were measured in the amputated and intact legs and the relationship between them was quantified using the SI. The results showed that the use of PFAA-MC decreases walking speed in ramp descent (P < 0.018). However, this was the only parameter that showed a significant change. Hence, the differences in the amputees’ gait pattern when using the above-mentioned prostheses may not be reflected by STP and their SI.
dc.languageeng
dc.publisherKorean Society of Mechanical Engineers
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://link.springer.com/10.1007/s12206-020-0145-0
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s12206-020-0145-0
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectADAPTIVE ANKLE PROSTHESIS
dc.subjectADAPTIVE ANKLE PROSTHESIS MICROCONTROLLED
dc.subjectENERGY STORAGE AND RETURN ANKLE PROSTHESIS
dc.subjectRAMP WALKING
dc.subjectTRANSTIBIAL AMPUTEE
dc.titleSpatio temporal parameters and symmetry in subjects ascending and descending a ramp, using three different prosthetic feet
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución