dc.creatorMaggio, Ruben Mariano
dc.creatorDamiani, Patricia Cecilia
dc.creatorOlivieri, Alejandro Cesar
dc.date.accessioned2021-03-09T12:40:36Z
dc.date.accessioned2022-10-15T11:58:45Z
dc.date.available2021-03-09T12:40:36Z
dc.date.available2022-10-15T11:58:45Z
dc.date.created2021-03-09T12:40:36Z
dc.date.issued2010-09
dc.identifierMaggio, Ruben Mariano; Damiani, Patricia Cecilia; Olivieri, Alejandro Cesar; Four-way kinetic-excitation-emission fluorescence data processed by multi-way algorithms. Determination of carbaryl and 1-naphthol in water samples in the presence of fluorescent interferents; Elsevier Science; Analytica Chimica Acta; 677; 2; 9-2010; 97-107
dc.identifier0003-2670
dc.identifierhttp://hdl.handle.net/11336/127803
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4383495
dc.description.abstractFour-way data were obtained by recording the kinetic evolution of excitation-emission fluorescence matrices for samples containing the analytes carbaryl and 1-naphthol, two widely employed pesticides, in the concentration ranges 0-363μgL-1 and 0-512μgL-1, respectively. The reaction followed was the alkaline hydrolysis of carbaryl to produce 1-naphthol, a fact which introduced strong linear dependencies and multi-linearity losses in the analyzed system. Data processing was performed with unfolded partial least-squares combined with residual trilinearization (U-PLS/RTL) and also with a suitably initialized and restricted parallel factor model (PARAFAC), combined with calibration based on multi-linear regression. U-PLS/RTL is shown to be significantly simpler in its implementation and to provide similar figures of merit. The applied chemometric strategy is able to successfully determine the analytes in water samples containing uncalibrated interferences, such as other commonly employed agrochemicals and also a naturally occurring background signal.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267010009530
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.aca.2010.07.045
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFOUR-WAY KINETIC FLUORESCENCE DATA
dc.subjectPARALLEL FACTOR ANALYSIS
dc.subjectRESIDUAL TRILINEARIZATION
dc.subjectSECOND-ORDER ADVANTAGE
dc.subjectUNFOLDED PARTIAL LEAST-SQUARES
dc.titleFour-way kinetic-excitation-emission fluorescence data processed by multi-way algorithms. Determination of carbaryl and 1-naphthol in water samples in the presence of fluorescent interferents
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución