Mammography parameters: compression, dose, and discomfort

dc.creatorBlanco, Susana Alicia Ana
dc.creatorDi Risio, Cecilia Diana
dc.creatorAndisco, D.
dc.creatorRojas, R. R.
dc.creatorRojas, R. M.
dc.date.accessioned2019-10-17T21:00:26Z
dc.date.accessioned2022-10-15T10:23:31Z
dc.date.available2019-10-17T21:00:26Z
dc.date.available2022-10-15T10:23:31Z
dc.date.created2019-10-17T21:00:26Z
dc.date.issued2017-04
dc.identifierBlanco, Susana Alicia Ana; Di Risio, Cecilia Diana; Andisco, D.; Rojas, R. R.; Rojas, R. M.; Parámetros mamográficos: compresión, dosis y disconfort; Elsevier; Revista Argentina de Radiología; 81; 2; 4-2017; 100-104
dc.identifier1852-9992
dc.identifierhttp://hdl.handle.net/11336/86225
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4375220
dc.description.abstractObjetivo: Confirmar la importancia de la compresión en mamografía, y relacionarla con eldisconfort manifestado por las pacientes.Materiales y métodos: Se emplearon 2 muestras de 402 y 268 mamografías, obtenidas en doscentros de diagnóstico que poseen el mismo equipo mamográfico pero diferentes técnicas decompresión. Las edades variaron entre los 21 y los 50 a?nos.Resultados: Se observó una sensible disminución en la dosis recibida a mayor compresión. Sinembargo, no se obtuvo una diferencia significativa en lo que respecta a los reclamos de laspacientes en relación con el disconfort experimentado.Discusión y Conclusión: La compresión en mamografía, siguiendo los estándares internacionalesde una fuerza entre 80-120 N, es efectiva en cuanto a la reducción de dosis, sin por eso serinsoportable para la paciente. Este disconfort tampoco está relacionado con la glandularidadde la mama.
dc.description.abstractObjective To confirm the importance of compression in mammography and relate it to the discomfort expressed by the patients. Materials and methods Two samples of 402 and 268 mammographies were obtained from two diagnostic centres that use the same mammographic equipment, but different compression techniques. The patient age range was from 21 to 50 years old. Results A significant decrease in the dose received was observed at higher compression. However, there was no significant difference as regards patients complaining about the discomfort experienced. Discussion and Conclusion Compression in mammography, following the international standards of a pressure between 80-120 N, is effective in reducing the dose without being unbearable for the patient. This discomfort is also unrelated to the glandularity of the breast
dc.languagespa
dc.publisherElsevier
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0048761917300492
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.rard.2017.04.006
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMAMA
dc.subjectMAMOGRAFÍA
dc.subjectCOMPRESIÓN
dc.titleParámetros mamográficos: compresión, dosis y disconfort
dc.titleMammography parameters: compression, dose, and discomfort
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución