dc.creatorBernabeu, Ezequiel Adrian
dc.creatorFlor, Sabrina Andrea
dc.creatorHöcht, Christian
dc.creatorTaira, Carlos Alberto
dc.creatorChiappetta, Diego Andrés
dc.creatorTripodi, Valeria Paula
dc.creatorLucangioli, Silvia Edith
dc.date.accessioned2020-06-03T19:14:09Z
dc.date.accessioned2022-10-15T10:12:36Z
dc.date.available2020-06-03T19:14:09Z
dc.date.available2022-10-15T10:12:36Z
dc.date.created2020-06-03T19:14:09Z
dc.date.issued2014-08
dc.identifierBernabeu, Ezequiel Adrian; Flor, Sabrina Andrea; Höcht, Christian; Taira, Carlos Alberto; Chiappetta, Diego Andrés; et al.; Development and validation of a highly sensitive HPLC method for determination of paclitaxel in pharmaceutical dosage forms and biological samples; Bentham Science Publishers; Current Pharmaceutical Analysis; 10; 3; 8-2014; 185-192
dc.identifier1573-4129
dc.identifierhttp://hdl.handle.net/11336/106618
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4374269
dc.description.abstractA new simple and highly sensitive HPLC-UV method for the analysis of paclitaxel in Taxol® and Abraxane® has been developed which also allows the quantification in biological samples of pharmacokimnetic studies with a very easy sample preparation. The proposed method has advantages over previously reported methods, such as an increase in sensitivity up to 20 times, good accuracy in terms of recovery that allows to work without addition of internal standard and a simple sample preparation in one step. The analysis was carried out using a Zorbax Eclipse XDB-C18 (4.6 × 150 mm, 3.5 μm) with a column guard. The mobile phase consisted of acetonitrile: water (50: 50) and the flow rate was 1 mL/min, the detection wavelength was 227 nm, the injection volume 5 μL and the analysis was performed at room temperature. The method was validated according ICH guidelines and FDA guidelines for validation of bioanalytical methods. Linearity was evaluated in the range from 0.005 ? 50.0 μg/mL, with a regression coefficient (R2) of 0.9967. LOD and LOQ were 0.001 and 0.005 μg/mL respectively.
dc.languageeng
dc.publisherBentham Science Publishers
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://eurekaselect.com/121495
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.2174/1573412910666140409002944
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectPACLITAXEL
dc.subjectHPLC-UV DETECTION
dc.subjectPHARMACEUTICAL FORMULATION
dc.subjectPHARMACOKINETIC STUDIES
dc.subjectVALIDATION
dc.titleDevelopment and validation of a highly sensitive HPLC method for determination of paclitaxel in pharmaceutical dosage forms and biological samples
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución