dc.creatorArancibia, Juan Alberto
dc.creatorRullo, Anabel
dc.creatorOlivieri, Alejandro Cesar
dc.creatorDi Nezio, Maria Susana
dc.creatorPistonesi, Marcelo Fabian
dc.creatorLista, Adriana Guillermina
dc.creatorFernández Band, Beatriz Susana
dc.date.accessioned2020-01-17T19:54:13Z
dc.date.accessioned2022-10-15T10:12:29Z
dc.date.available2020-01-17T19:54:13Z
dc.date.available2022-10-15T10:12:29Z
dc.date.created2020-01-17T19:54:13Z
dc.date.issued2004-06
dc.identifierArancibia, Juan Alberto; Rullo, Anabel; Olivieri, Alejandro Cesar; Di Nezio, Maria Susana; Pistonesi, Marcelo Fabian; et al.; Fast spectrophotometric determination of fluoride in ground waters by flow injection using partial least-squares calibration; Elsevier Science; Analytica Chimica Acta; 512; 1; 6-2004; 157-163
dc.identifier0003-2670
dc.identifierhttp://hdl.handle.net/11336/95094
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4374258
dc.description.abstractThe presence of sulphate constitutes a serious interference in the usual zirconium lake-based spectrophotometric method for the determination of fluoride in water. In this report, full spectral data have been recorded for the zirconium lake of 2-(parasulfophenylazo)-1,8-dihydroxy-3,6-naphthalene- disulfonate (SPADNS) in the simultaneous presence of fluoride and sulphate, as obtained with a flow injection system with a diode-array detector. The information has been processed with partial least-squares (PLS) multivariate calibration. Adequate modeling using a sixteen-sample calibration set allows fluoride to be determined in ground waters by the automated flow injection method, even in the presence of sulphate in concentrations up to 1000 mg l -1. In the calibration range 0-1.50 mg l-1 for fluoride, the limit of detection is 0.1 mg l-1. The fluoride contents in real samples, as determined with the present method, were satisfactorily compared with those provided by ion selective potentiometry.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267004002168
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2004.02.026
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFLOW INJECTION ANALYSIS
dc.subjectFLUORIDE ANALYSIS
dc.subjectGROUND WATERS
dc.subjectPARTIAL LEAST-SQUARES REGRESSION
dc.subjectSULPHATE INTERFERENCE
dc.titleFast spectrophotometric determination of fluoride in ground waters by flow injection using partial least-squares calibration
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución