dc.creator | Arancibia, Juan Alberto | |
dc.creator | Rullo, Anabel | |
dc.creator | Olivieri, Alejandro Cesar | |
dc.creator | Di Nezio, Maria Susana | |
dc.creator | Pistonesi, Marcelo Fabian | |
dc.creator | Lista, Adriana Guillermina | |
dc.creator | Fernández Band, Beatriz Susana | |
dc.date.accessioned | 2020-01-17T19:54:13Z | |
dc.date.accessioned | 2022-10-15T10:12:29Z | |
dc.date.available | 2020-01-17T19:54:13Z | |
dc.date.available | 2022-10-15T10:12:29Z | |
dc.date.created | 2020-01-17T19:54:13Z | |
dc.date.issued | 2004-06 | |
dc.identifier | Arancibia, Juan Alberto; Rullo, Anabel; Olivieri, Alejandro Cesar; Di Nezio, Maria Susana; Pistonesi, Marcelo Fabian; et al.; Fast spectrophotometric determination of fluoride in ground waters by flow injection using partial least-squares calibration; Elsevier Science; Analytica Chimica Acta; 512; 1; 6-2004; 157-163 | |
dc.identifier | 0003-2670 | |
dc.identifier | http://hdl.handle.net/11336/95094 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4374258 | |
dc.description.abstract | The presence of sulphate constitutes a serious interference in the usual zirconium lake-based spectrophotometric method for the determination of fluoride in water. In this report, full spectral data have been recorded for the zirconium lake of 2-(parasulfophenylazo)-1,8-dihydroxy-3,6-naphthalene- disulfonate (SPADNS) in the simultaneous presence of fluoride and sulphate, as obtained with a flow injection system with a diode-array detector. The information has been processed with partial least-squares (PLS) multivariate calibration. Adequate modeling using a sixteen-sample calibration set allows fluoride to be determined in ground waters by the automated flow injection method, even in the presence of sulphate in concentrations up to 1000 mg l -1. In the calibration range 0-1.50 mg l-1 for fluoride, the limit of detection is 0.1 mg l-1. The fluoride contents in real samples, as determined with the present method, were satisfactorily compared with those provided by ion selective potentiometry. | |
dc.language | eng | |
dc.publisher | Elsevier Science | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267004002168 | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2004.02.026 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | FLOW INJECTION ANALYSIS | |
dc.subject | FLUORIDE ANALYSIS | |
dc.subject | GROUND WATERS | |
dc.subject | PARTIAL LEAST-SQUARES REGRESSION | |
dc.subject | SULPHATE INTERFERENCE | |
dc.title | Fast spectrophotometric determination of fluoride in ground waters by flow injection using partial least-squares calibration | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |