dc.creatorBorque, Paloma Celina
dc.creatorVidal, Luciano
dc.creatorRugna, Martin Ezequiel
dc.creatorLang, Timothy J.
dc.creatorNicora, Maria Gabriela
dc.creatorNesbitt, Stephen William
dc.date.accessioned2021-10-15T02:48:55Z
dc.date.accessioned2022-10-15T09:00:11Z
dc.date.available2021-10-15T02:48:55Z
dc.date.available2022-10-15T09:00:11Z
dc.date.created2021-10-15T02:48:55Z
dc.date.issued2020-10
dc.identifierBorque, Paloma Celina; Vidal, Luciano; Rugna, Martin Ezequiel; Lang, Timothy J.; Nicora, Maria Gabriela; et al.; Distinctive Signals in 1‐minute Observations of Overshooting Tops and Lightning Activity in a Severe Supercell Thunderstorm; Blackwell Publishing Ltd; Journal of Geophysical Research: Atmospheres; 125; 20; 10-2020; 1-38
dc.identifier2169-8996
dc.identifierhttp://hdl.handle.net/11336/143737
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4367886
dc.description.abstractThis work examines a severe weather event that took place over central Argentina on 11 December 2018. The evolution of the storm from its initiation, rapid organization into a supercell, and eventual decay was analyzed with high-temporal resolution observations. This work provides insight into the spatio-temporal co-evolution of storm kinematics (updraft area and lifespan), cloud-top cooling rates, and lightning production that led to severe weather. The analyzed storm presented two convective periods with associated severe weather. An overall decrease in cloud-top local minima IR brightness temperature (MinIR) and lightning jump (LJ) preceded both periods. LJs provided the highest lead time to the occurrence of severe weather, with the ground-based lightning networks providing the maximum warning time of around 30 min. Lightning flash counts from the Geostationary Lightning Mapper (GLM) were underestimated when compared to detections from ground-based lightning networks. Among the possible reasons for GLM's lower detection efficiency were an optically dense medium located above lightning sources and the occurrence of flashes smaller than GLM's footprint. The minimum MinIR provided the shorter warning time to severe weather occurrence. However, the secondary minima in MinIR that preceded the absolute minima improved this warning time by more than 10 min. Trends in MinIR for time scales shorter than 6 min revealed shorter cycles of fast cooling and warming, which provided information about the lifecycle of updrafts within the storm. The advantages of using observations with high-temporal resolution to analyze the evolution and intensity of convective storms are discussed.
dc.languageeng
dc.publisherBlackwell Publishing Ltd
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1029/2020JD032856
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1029/2020JD032856
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAEROSOL TRANSPORT
dc.subjectATMOSPHERIC MODELING
dc.subjectLARGE EDDY SIMULATION (LES)
dc.subjectRANDOM WALK
dc.subjectSEA SPRAY GENERATION
dc.subjectUPSCALED MODELING
dc.titleDistinctive Signals in 1‐minute Observations of Overshooting Tops and Lightning Activity in a Severe Supercell Thunderstorm
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución