Street lighting energy efficiency

dc.creatorTapia Garzón, J.
dc.creatorManzano, Eduardo Roberto
dc.creatorGao, S.
dc.creatorRojas, M.
dc.creatorFernandez Nobrega, Marcela Noris
dc.date.accessioned2020-03-26T20:11:16Z
dc.date.accessioned2022-10-15T08:51:05Z
dc.date.available2020-03-26T20:11:16Z
dc.date.available2022-10-15T08:51:05Z
dc.date.created2020-03-26T20:11:16Z
dc.date.issued2009-06
dc.identifierTapia Garzón, J.; Manzano, Eduardo Roberto; Gao, S.; Rojas, M.; Fernandez Nobrega, Marcela Noris; Eficiencia energética en el alumbrado publico; Asociación Argentina de Energía Solar; Energías Renovables y Medio Ambiente; 23; 6-2009; 33-39
dc.identifier0328-932X
dc.identifierhttp://hdl.handle.net/11336/101005
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4367120
dc.description.abstractUn estudio sobre la optimización de la eficiencia energética en el alumbrado público de la Municipalidad de S. M. de Tucumán fue efectuado basado en la aplicación de relojes astronómicos, balastos electrónicos dimerizables para lámparas de descarga de Sodio de alta presión de 150W/100W y luminarias de alta eficiencia. Durante 45 días, 273 puntos de luz conectados a 6 redes de alumbrado independientes fueron monitoreados, registrando el consumo, tiempos de funcionamiento, apagados nocturnos, encendidos diurnos y parámetros eléctricos de calidad. Los resultados indican que es posible una importante reducción en el consumo, entre un 11% y un 43% mejorando la calidad del servicio y reduciendo el contenido de armónicos que se introducen a la red de alumbrado a TDH A ≤ 6,5%. El trabajo describe la experiencia y el análisis de los resultados obtenidos.
dc.description.abstractA study of street lighting energy efficiency was carried out in S. M. Tucumán City, based on the application of astronomical clocks, electronic ballasts (control gear) for high pressure sodium 150W/100W lamps and high efficiency luminaires. During 45 days, 273 luminaires connected to 6 independent electric networks were monitored recording: energy consumption, switching on/off times, night lamps outages, day on lamps and electrical quality parameters. The results indicate that it is possible a significant reduction in consumption, between 11% and 43% while improving service quality and reducing the harmonic content being introduced to the network lighting by TDH A ≤ 6.5%. The paper describes the experience and the analysis of the results.
dc.languagespa
dc.publisherAsociación Argentina de Energía Solar
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEficiencia Energetica
dc.subjectAlumbrado Urbano
dc.subjectBalastos Electronicos
dc.subjectArmonicos Electricos
dc.titleEficiencia energética en el alumbrado publico
dc.titleStreet lighting energy efficiency
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución