dc.creatorBergant, Marcos Antonio
dc.creatorYawny, Alejandro Andres
dc.creatorPerez Ipiña, Juan Elias
dc.date.accessioned2019-04-30T14:09:04Z
dc.date.accessioned2022-10-15T08:43:24Z
dc.date.available2019-04-30T14:09:04Z
dc.date.available2022-10-15T08:43:24Z
dc.date.created2019-04-30T14:09:04Z
dc.date.issued2017-04
dc.identifierBergant, Marcos Antonio; Yawny, Alejandro Andres; Perez Ipiña, Juan Elias; J-resistance curves for Inconel 690 and Incoloy 800 nuclear steam generators tubes at room temperature and at 300 °C; Elsevier Science; Journal of Nuclear Materials; 486; 4-2017; 298-307
dc.identifier0022-3115
dc.identifierhttp://hdl.handle.net/11336/75295
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4366397
dc.description.abstractThe structural integrity of steam generator tubes is a relevant issue concerning nuclear plant safety. In the present work, J-resistance curves of Inconel 690 and Incoloy 800 nuclear steam generator tubes with circumferential and longitudinal through wall cracks were obtained at room temperature and 300 °C using recently developed non-standard specimens' geometries. It was found that Incoloy 800 tubes exhibited higher J-resistance curves than Inconel 690 for both crack orientations. For both materials, circumferential cracks resulted into higher fracture resistance than longitudinal cracks, indicating a certain degree of texture anisotropy introduced by the tube fabrication process. From a practical point of view, temperature effects have found to be negligible in all cases. The results obtained in the present work provide a general framework for further application to structural integrity assessments of cracked tubes in a variety of nuclear steam generator designs.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0022311516307012
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jnucmat.2017.01.040
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFRACTURE TOUGHNESS
dc.subjectINCOLOY 800
dc.subjectINCONEL 690
dc.subjectJ-RESISTANCE CURVE
dc.subjectNON-STANDARD SPECIMENS
dc.subjectSTEAM GENERATOR TUBES
dc.titleJ-resistance curves for Inconel 690 and Incoloy 800 nuclear steam generators tubes at room temperature and at 300 °C