Behavior of post-installed adhesive anchors in cracked concrete under tension loads.

dc.creatorRoldan, Victor Alejandro
dc.creatorPalazzo, Gustavo Luís
dc.creatorMaldonado, Noemi Graciela
dc.creatorGuzmán, Marcelo Nicolás
dc.creatorCalderón, Francisco Alberto
dc.date.accessioned2020-03-25T15:27:19Z
dc.date.accessioned2022-10-15T08:06:38Z
dc.date.available2020-03-25T15:27:19Z
dc.date.available2022-10-15T08:06:38Z
dc.date.created2020-03-25T15:27:19Z
dc.date.issued2016-11
dc.identifierRoldan, Victor Alejandro; Palazzo, Gustavo Luís; Maldonado, Noemi Graciela; Guzmán, Marcelo Nicolás; Calderón, Francisco Alberto; Comportamiento de anclajes químicos post instalados en hormigón fisurado bajo solicitaciones de tracción; Universidad de las Fuerzas Armadas; Revista Internacional de Ingeniería de Estructuras; 22; 1; 11-2016; 71-84
dc.identifier1390-0315
dc.identifierhttp://hdl.handle.net/11336/100693
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4363521
dc.description.abstractHoy en día los anclajes químicos son ampliamente utilizados para la rehabilitación de estructuras de hormigón armado existentes. Esto es debido a que son muy versátiles a la hora de incorporar elementos estructurales metálicos de refuerzo, como por ejemplo riostras metálicas a estructuras de hormigón existentes. En el presente trabajo se estudia la influencia de la fisuración en la capacidad portante de los anclajes químicos sometidos a tracción. Para tal fin se estudió cuáles son los anchos de fisura posibles que pueden presentarse en una estructura de hormigón existente. Posteriormente se realizaron ensayos de arrancamiento de anclajes colocados en bloques de hormigón fisurados y sin fisurar. Los resultados obtenidos se compararon con las ecuaciones para cálculo de capacidad de anclajes dadas en la normativa norteamericana para cálculo de hormigón ACI318-14. Estanormativa no contempla el uso de anclajes en hormigones en los que no es posible controlar el ancho de fisura, por lo que sobrevalora su capacidad. Finalmente se presentan las conclusiones relevantes del estudio realizado.
dc.description.abstractNowadays the adhesive anchors are widely used in the retrofitting of existing concrete structures. The adhesive anchors are a versatile way to attach new metallic structural components, as metallic braces, to the existing concrete structure. In this paper the influence of the cracking in the adhesive anchor tensile capacity is evaluated. For that end the possible crack widths that may occur in existing concrete structures were studied. Later a series of pull-out tests of adhesive anchors placed in uncracked and cracked concrete were performed. The tests results were compared with the equations for the calculation of the anchor tensile capacity given in the structural concrete standard ACI 318-14. This standard does not contemplate the use of adhesive anchors on existing concrete structures where the crack width cannot be controlled, so overestimates the tensile capacity of these anchors. Finally the main conclusions of the study conducted are presented.
dc.languagespa
dc.publisherUniversidad de las Fuerzas Armadas
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://journal.espe.edu.ec/ojs/index.php/riie/article/view/630
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectanclajes químicos
dc.subjecthormigón fisurado
dc.subjectensayos de arrancamiento
dc.titleComportamiento de anclajes químicos post instalados en hormigón fisurado bajo solicitaciones de tracción
dc.titleBehavior of post-installed adhesive anchors in cracked concrete under tension loads.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion