dc.creatorSilva Do Nascimento, Danielle
dc.creatorVolpe, Verónica
dc.creatorInsausti, Matías
dc.creatorGrunhut, Marcos
dc.date.accessioned2022-05-20T10:25:00Z
dc.date.accessioned2022-10-15T07:10:06Z
dc.date.available2022-05-20T10:25:00Z
dc.date.available2022-10-15T07:10:06Z
dc.date.created2022-05-20T10:25:00Z
dc.date.issued2021-04-26
dc.identifierSilva Do Nascimento, Danielle; Volpe, Verónica; Insausti, Matías; Grunhut, Marcos; On line kinetic analysis of permeation profiles for UV filter loaded microemulsions using an automatic system with spectroscopic detection and a chemometric approach; Royal Society of Chemistry; RSC Advances; 11; 26; 26-4-2021; 15528-15538
dc.identifier2046-2069
dc.identifierhttp://hdl.handle.net/11336/157890
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4358911
dc.description.abstractThe analysis of the permeation kinetics of new UV filter formulations is of great importance since the kinetic parameters are related to the effectiveness of the product over time. The dynamics of this process can be evaluated by means of the calculation of the permeation kinetic constants, which can be obtained from the respective permeation profiles. This paper is aimed at improving the analytical performance of permeation assays using an on-line automatic system with spectrometric detection avoiding the chromatographic procedure and the usually manual sampling steps required using the traditional Franz diffusion cell. Then, the kinetics of permeation of octyl p-methoxycinnamate loaded in different microemulsions through a synthetic membrane (polyamide) was analysed at real time by UV-Vis and fluorescence spectroscopies. The spectral data were obtained at regular intervals of time (5 min) during 60 min, and the concentration of the permeated UV-filter was at each time calculated using univariate linear calibration. The interference caused by the presence of basil essential oil (oily phase) in some microemulsion samples was overcome using synchronous fluorescence spectroscopy (Δλ = 60 nm) and partial least squares. In all cases, the permeation profiles were obtained (first-order kinetics) and the respective permeation kinetic constants were calculated. The validation of the proposed method was assessed by gas chromatographic-mass spectroscopy and non-significant differences for the obtained permeation kinetic constants were found between methods (p = 0.05). Additionally, a commercial sample was analysed with the proposed methods and the results were validated by high performance liquid chromatography technique.
dc.languageeng
dc.publisherRoyal Society of Chemistry
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/d1ra01067k
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://pubs.rsc.org/en/content/articlelanding/2021/ra/d1ra01067k
dc.rightshttps://creativecommons.org/licenses/by-nc/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectESSENTIAL OILS
dc.subjectFLUORESCENCE
dc.subjectFLUORESCENCE SPECTROSCOPY
dc.subjectGAS CHROMATOGRAPHY
dc.subjectHIGH PERFORMANCE LIQUID CHROMATOGRAPHY
dc.subjectKINETICS
dc.subjectLEAST SQUARES APPROXIMATIONS
dc.subjectMASS SPECTROMETRY
dc.subjectMICROEMULSIONS
dc.subjectSPECTROSCOPIC ANALYSIS
dc.subjectSPECTRUM ANALYSIS
dc.titleOn line kinetic analysis of permeation profiles for UV filter loaded microemulsions using an automatic system with spectroscopic detection and a chemometric approach
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución