dc.creatorMortera, Pablo
dc.creatorZuljan, Federico Alberto
dc.creatorMagni, Christian
dc.creatorBortolato, Santiago Andres
dc.creatorAlarcon, Sergio Hugo
dc.date.accessioned2019-10-23T21:05:12Z
dc.date.accessioned2022-10-15T05:47:51Z
dc.date.available2019-10-23T21:05:12Z
dc.date.available2022-10-15T05:47:51Z
dc.date.created2019-10-23T21:05:12Z
dc.date.issued2018-02
dc.identifierMortera, Pablo; Zuljan, Federico Alberto; Magni, Christian; Bortolato, Santiago Andres; Alarcon, Sergio Hugo; Multivariate analysis of organic acids in fermented food from reversed-phase high-performance liquid chromatography data; Elsevier Science; Talanta; 178; 2-2018; 15-23
dc.identifier0039-9140
dc.identifierhttp://hdl.handle.net/11336/87182
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4351572
dc.description.abstractMultivariate calibration coupled to RP-HPLC with diode array detection (HPLC-DAD) was applied to the identification and the quantitative evaluation of the short chain organic acids (malic, oxalic, formic, lactic, acetic, citric, pyruvic, succinic, tartaric, propionic and α-cetoglutaric) in fermented food. The goal of the present study was to get the successful resolution of a system in the combined occurrence of strongly coeluting peaks, of distortions in the time sensors among chromatograms, and of the presence of unexpected compounds not included in the calibration step. Second-order HPLC-DAD data matrices were obtained in a short time (10 min) on a C18 column with a chromatographic system operating in isocratic mode (mobile phase was 20 mmol L−1 phosphate buffer at pH 2.20) and a flow-rate of 1.0 mL min−1 at room temperature. Parallel factor analysis (PARAFAC) and unfolded partial least-squares combined with residual bilinearization (U-PLS/RBL) were the second-order calibration algorithms select for data processing. The performance of the analytical parameters was good with an outstanding limit of detection (LODs) for acids ranging from 0.15 to 10.0 mmol L−1 in the validation samples. The improved method was applied to the analysis of many dairy products (yoghurt, cultured milk and cheese) and wine. The method was shown as an effective means for determining and following acid contents in fermented food and was characterized by reducibility with simple, high resolution and rapid procedure without derivatization of analytes.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0039914017309372
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2017.09.005
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Argentina (CC BY-NC-SA 2.5 AR)
dc.subjectDAIRY PRODUCTS
dc.subjectMULTIVARIATE ANALYSIS
dc.subjectRP-HPLC
dc.subjectSHORT CHAIN ORGANIC ACIDS
dc.titleMultivariate analysis of organic acids in fermented food from reversed-phase high-performance liquid chromatography data
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución