dc.creatorBurgos Mariguin, Carlos Alberto
dc.creatorBatista Abreu, Jean C.
dc.creatorCalabró, Horacio Daniel
dc.creatorJaca, Rossana Claudia
dc.creatorGodoy, Luis Augusto
dc.date.accessioned2020-04-16T19:53:59Z
dc.date.accessioned2022-10-15T05:45:08Z
dc.date.available2020-04-16T19:53:59Z
dc.date.available2022-10-15T05:45:08Z
dc.date.created2020-04-16T19:53:59Z
dc.date.issued2015-06
dc.identifierBurgos Mariguin, Carlos Alberto; Batista Abreu, Jean C.; Calabró, Horacio Daniel; Jaca, Rossana Claudia; Godoy, Luis Augusto; Buckling estimates for oil storage tanks: Effect of simplified modeling of the roof and wind girder; Elsevier; Thin-Walled Structures; 91; 6-2015; 29-37
dc.identifier0263-8231
dc.identifierhttp://hdl.handle.net/11336/102796
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4351301
dc.description.abstractOil storage tanks are short cylindrical shells fabricated with an external fixed roof or floating roof on the inside. Some features of the structure tend to be simplified in practice and research in order to perform stability and strength analyses using a much simpler model. This paper considers the structural consequences of such simplifications, including the substitution of a supporting structure of the roof or a wind girder by an equivalent thickness or by a fictitious boundary condition. Three load cases are investigated: thermal loads due to an adjacent fire, uniform external pressure, and wind pressure. Results of finite element analyses to evaluate bifurcation loads and modes are reported as estimates of buckling. Equivalent thickness models are derived by establishing equivalences in moment of inertia or sectional modulus of the components that are not represented in detail. The differences in buckling loads associated with equivalent thickness models depends on the load case considered, but range between 7-15% for a case studied with a fixed roof, with smaller differences (3%) for opened top tanks with wind girders. Substitution of a wind girder by a boundary condition, on the other hand, yields large errors under thermal loads exceeding 80% of buckling loads.
dc.languageeng
dc.publisherElsevier
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0263823115000403
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.tws.2015.02.006
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFINITE ELEMENT ANALYSIS
dc.subjectPRESSURE
dc.subjectSHELLS
dc.subjectTANKS
dc.subjectTHERMAL LOADS
dc.subjectWIND PRESSURES
dc.titleBuckling estimates for oil storage tanks: Effect of simplified modeling of the roof and wind girder
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion