dc.creator | Marchisio, Patricia Fátima | |
dc.creator | Sales, Adriana María | |
dc.creator | Cerutti, Estela Soledad | |
dc.creator | Marchevski, E. | |
dc.creator | Martinez, Luis Dante | |
dc.date.accessioned | 2020-03-06T17:30:26Z | |
dc.date.accessioned | 2022-10-15T05:44:34Z | |
dc.date.available | 2020-03-06T17:30:26Z | |
dc.date.available | 2022-10-15T05:44:34Z | |
dc.date.created | 2020-03-06T17:30:26Z | |
dc.date.issued | 2005-09 | |
dc.identifier | Marchisio, Patricia Fátima; Sales, Adriana María; Cerutti, Estela Soledad; Marchevski, E.; Martinez, Luis Dante; On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES; Elsevier Science; Journal of Hazardous Materials; 124; 1-3; 9-2005; 113-118 | |
dc.identifier | 0304-3894 | |
dc.identifier | http://hdl.handle.net/11336/98935 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4351260 | |
dc.description.abstract | The present paper proposes an on-line preconcentration procedure for lead determination in Ilex paraguariensis (St. Hilaire) samples by ultrasonic nebulization associated to inductively coupled plasma optical emission spectrometry (USN-ICP-OES). It is based on the precipitation of lead(II) ion on a minicolumn packed with polyurethane foam using 2-(5-bromo-2-pyridilazo)-5- diethylaminophenol (5-Br-PADAP) as precipitating reagent. The collected analyte precipitate was quantitatively eluted from the minicolumn with 20% (v/v) nitric acid. An enhancement factor of 225-fold was obtained (15 for USN and 15 for preconcentration). The detection limit (DL) value for the preconcentration of 10.0 ml of sample was 40.0 ng/l. The relative standard deviation (R.S.D.) was 3.0% for a Pb concentration of 1 μg/l, calculated from the peak heights obtained. The calibration graph using the preconcentration system for lead was linear with a correlation coefficient of 0.9997, at levels near the detection limits up to at least 100 μg/l. The preconcentration procedure was successfully applied to the determination of lead in mate tea samples. | |
dc.language | eng | |
dc.publisher | Elsevier Science | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jhazmat.2005.04.017 | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0304389405002001 | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | LEAD DETERMINATION | |
dc.subject | MATE TEA SAMPLES | |
dc.subject | ON-LINE PRECONCENTRATION | |
dc.subject | POLYURETHANE FOAM | |
dc.subject | USN-ICP-OES | |
dc.title | On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |