dc.creator | Fantino, Roberto Armin | |
dc.creator | Busada, Claudio A. | |
dc.creator | Solsona, Jorge Alberto | |
dc.date.accessioned | 2020-04-28T21:40:17Z | |
dc.date.accessioned | 2022-10-15T04:46:21Z | |
dc.date.available | 2020-04-28T21:40:17Z | |
dc.date.available | 2022-10-15T04:46:21Z | |
dc.date.created | 2020-04-28T21:40:17Z | |
dc.date.issued | 2019-07 | |
dc.identifier | Fantino, Roberto Armin; Busada, Claudio A.; Solsona, Jorge Alberto; Observer-Based Grid-Voltage Sensorless Synchronization and Control of a VSI-LCL Tied to an Unbalanced Grid; Institute of Electrical and Electronics Engineers; Ieee Transactions On Industrial Electronics; 66; 7; 7-2019; 4972-4981 | |
dc.identifier | 0278-0046 | |
dc.identifier | http://hdl.handle.net/11336/103846 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4346465 | |
dc.description.abstract | This paper proposes an observer-based grid-voltage sensorless strategy that allows to implement the synchronization and control of an LCL grid-tied voltage source inverter. By using exclusively the measurement of the current injected to the grid, an observer estimates both fundamental positive- and negative-sequence components of the grid voltage, with a quality (in terms of total harmonic distortion and convergence speed) comparable to that obtained with a classic double second-order generalized integrator-frequency-locked loop (DSOGI-FLL). The unmeasured LCL filter states are also estimated by the observer, and they are used to implement a full-state feedback control strategy suitable for low resonance frequency LCL filters. The effectiveness of the scheme proposed here is demonstrated by comparison with a DSOGI-FLL and with a controller recently proposed in the literature. Experimental and simulation results that demonstrate the validity and effectiveness of the proposal are presented. | |
dc.language | eng | |
dc.publisher | Institute of Electrical and Electronics Engineers | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/8458369 | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1109/TIE.2018.2868255 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | OBSERVERS | |
dc.subject | SYNCHRONIZATION | |
dc.subject | VOLTAGE MEASUREMENT | |
dc.title | Observer-Based Grid-Voltage Sensorless Synchronization and Control of a VSI-LCL Tied to an Unbalanced Grid | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |