dc.creatorCebeiro, Javier
dc.creatorNguyen, M. K.
dc.creatorMorvidone, Marcela Alejandra
dc.creatorNoumowé, A.
dc.date.accessioned2019-10-17T20:58:23Z
dc.date.accessioned2022-10-15T03:26:51Z
dc.date.available2019-10-17T20:58:23Z
dc.date.available2022-10-15T03:26:51Z
dc.date.created2019-10-17T20:58:23Z
dc.date.issued2017-11
dc.identifierCebeiro, Javier; Nguyen, M. K.; Morvidone, Marcela Alejandra; Noumowé, A.; New “improved” Compton scatter tomography modality for investigative imaging of one-sided large objects; Taylor & Francis Ltd; Inverse Problems In Science And Engineering; 25; 11; 11-2017; 1676-1696
dc.identifier1741-5977
dc.identifierhttp://hdl.handle.net/11336/86224
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4339966
dc.description.abstractIn an effort to promote Compton scatter tomography (CST) as an adequate modality for imaging the inner parts of large objects limited in a half-space of ℝ, we show that the standard CST can be ‘improved’ in some particular sense by ‘doubling’ the scanning mechanism. To this end, one needs to record for each position of a detector the scattered flux densities at two energies of scattered radiation, instead of one. Curiously, thanks to geometric inversion, this ‘double’ scanning may be converted into a transmission scanning on an apparent object, not along a straight line path as usual, but along a folded line in the shape of a V-line path. It has been proved that this V-line transmission scanning admits a well-defined reconstruction procedure. Therefore, the proposed CST with ‘double’ scanning, which solves the above imaging inverse problem, shows an ‘improved’ reconstructed image as compared to the standard one. We present theoretical arguments to support this claim as well as numerical simulations to illustrate its working and its viability.
dc.languageeng
dc.publisherTaylor & Francis Ltd
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/abs/10.1080/17415977.2017.1281920
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1080/17415977.2017.1281920
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCOMPTON SCATTERING
dc.subjectGAMMA-RAY IMAGING
dc.subjectRADON TRANSFORM ON A PAIR OF SUPPLEMENTARY CIRCULAR ARCS
dc.subjectRADON TRANSFORMS
dc.subjectV-LINE RADON TRANSFORM
dc.titleNew “improved” Compton scatter tomography modality for investigative imaging of one-sided large objects
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución