dc.creatorCulzoni, Maria Julia
dc.creatorAucelio, Ricardo Q.
dc.creatorEscandar, Graciela Monica
dc.date.accessioned2020-06-23T20:04:11Z
dc.date.accessioned2022-10-15T03:24:49Z
dc.date.available2020-06-23T20:04:11Z
dc.date.available2022-10-15T03:24:49Z
dc.date.created2020-06-23T20:04:11Z
dc.date.issued2012-06
dc.identifierCulzoni, Maria Julia; Aucelio, Ricardo Q.; Escandar, Graciela Monica; High-performance liquid chromatography with fast-scanning fluorescence detection and multivariate curve resolution for the efficient determination of galantamine and its main metabolites in serum; Elsevier Science; Analytica Chimica Acta; 740; 6-2012; 27-35
dc.identifier0003-2670
dc.identifierhttp://hdl.handle.net/11336/107996
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4339795
dc.description.abstractBased on green analytical chemistry principles, an efficient approach was applied for the simultaneous determination of galantamine, a widely used cholinesterase inhibitor for the treatment of Alzheimer's disease, and its major metabolites in serum samples. After a simple serum deproteinization step, second-order data were rapidly obtained (less than 6 min) with a chromatographic system operating in the isocratic regime using ammonium acetate/acetonitrile (94:6) as mobile phase. Detection was made with a fast-scanning spectrofluorimeter, which allowed the efficient collection of data to obtain matrices of fluorescence intensity as a function of retention time and emission wavelength. Successful resolution was achieved in the presence of matrix interferences in serum samples using multivariate curve resolution-alternating least-squares (MCR-ALS). The developed approach allows the quantification of the analytes at levels found in treated patients, without the need of applying either preconcentration or extraction steps. Limits of detection in the range between 8 and 11 ng mL−1, relative prediction errors from 7 to 12% and coefficients of variation from 4 to 7% were achieved.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267012009026
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.aca.2012.06.034
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCHROMATOGRAPHY
dc.subjectSPECTROFLUORIMETRY
dc.subjectMULTIVARIATE CALIBRATION
dc.subjectGALANTAMINE
dc.titleHigh-performance liquid chromatography with fast-scanning fluorescence detection and multivariate curve resolution for the efficient determination of galantamine and its main metabolites in serum
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución