dc.creatorFarias, Gustavo Marcelo
dc.creatorWuilloud, Rodolfo German
dc.creatorMoyano, Susana
dc.creatorGasquez, José Antonio
dc.creatorOlsina, Roberto Antonio
dc.creatorMartinez, Luis Dante
dc.date.accessioned2020-03-27T21:03:06Z
dc.date.accessioned2022-10-15T02:27:06Z
dc.date.available2020-03-27T21:03:06Z
dc.date.available2022-10-15T02:27:06Z
dc.date.created2020-03-27T21:03:06Z
dc.date.issued2002-09-01
dc.identifierFarias, Gustavo Marcelo; Wuilloud, Rodolfo German; Moyano, Susana; Gasquez, José Antonio; Olsina, Roberto Antonio; et al.; Determination of cobalt in urine by FI-ICP-AES with online preconcentration; Preston Publ Inc; Journal Of Analytical Toxicology; 26; 6; 1-9-2002; 360-364
dc.identifier0146-4760
dc.identifierhttp://hdl.handle.net/11336/101189
dc.identifier1945-2403
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4335005
dc.description.abstractA method for the preconcentration and determination of cobalt in human urine samples was developed. The online preconcentration and determination were attained using inductively coupled plasma atomic emission spectromety (ICP-AES) coupled to a flow injection (FI) method. Cobalt was retained on an Amberlite XAD-7 resin as cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex at pH 9.5. Cobalt was removed from the microcolumn with perchloric acid. A sensitivity enhancement factor of 90 was obtained with respect to cobalt determination by ICP-AES without preconcentration. The value of detection limit for the preconcentration method proposed was 25 ng/L. The precision for 10 replicate determinations at the 5 mg/L (mean ± SD, 5.1 ± 0.14) Co level was 2.7% relative standard deviation, calculated from the peak heights obtained. The calibration graph preconcentration method for cobalt was linear with a correlation coefficient of 0.9994 from approximately 0.25 mg/L up to at least 100 mg/L. The method was successfully applied to the determination of cobalt in human urine samples.
dc.languageeng
dc.publisherPreston Publ Inc
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://academic.oup.com/jat/article/26/6/360/703298
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1093/jat/26.6.360
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCOBALT
dc.subjectHUMAN ORINE SAMPLES
dc.subjectINDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETY
dc.subjectFLOW INJECTION
dc.titleDetermination of cobalt in urine by FI-ICP-AES with online preconcentration
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución