dc.creatorColombo, Lucas
dc.creatorGaray, Fernando Sebastian
dc.date.accessioned2018-11-13T18:03:31Z
dc.date.accessioned2022-10-15T01:54:55Z
dc.date.available2018-11-13T18:03:31Z
dc.date.available2022-10-15T01:54:55Z
dc.date.created2018-11-13T18:03:31Z
dc.date.issued2017-10
dc.identifierColombo, Lucas; Garay, Fernando Sebastian; A robust and practically free of charge intermittent use glucose biosensor; Elsevier Science Sa; Sensors and Actuators B: Chemical; 256; 10-2017; 751-759
dc.identifier0925-4005
dc.identifierhttp://hdl.handle.net/11336/64341
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4332396
dc.description.abstractIn the past decades, great effort has been put in finding new electrode surface modifiers and enzyme immobilizer agents that prevent the enzyme leakage, minimize the effect of interfering species, retain the enzyme bioactivity, and enhance the sensor sensitivity. In this work, a sandwich-type glucose biosensor that keeps its sensitivity and operational linear range for more than a year is presented. After 5 months of intermittent use, where the biosensor was exposed to more than 500 standard additions, it presented a limit of detection of 5 μM, and the linear behavior was from 5 μM to 3 mM with a value of r2 = 0.999. Besides, after 7 months of its assembling, the biosensor was employed for assessing the glucose concentration of real serum samples and its performance was compared with the response of a commercial autoanalyzer. A year later, the biosensor still exhibited very good performance of its analytical parameters. The performance of identical sandwich-type biosensors is analyzed when they are exposed to three different storage conditions. Simulated curves are compared with experimental data to explain the dependence of sensitivity and response-time on the aging and storage conditions of the biosensors.
dc.languageeng
dc.publisherElsevier Science Sa
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.snb.2017.10.010
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0925400517318907
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBIOSENSOR
dc.subjectCHRONOAMPEROMETRY
dc.subjectDIABETES
dc.subjectGLUCOSE
dc.subjectINTERMITTENT USE
dc.subjectLONG-TERM STABILITY
dc.titleA robust and practically free of charge intermittent use glucose biosensor
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución