dc.creatorAcebal, Carolina Cecilia
dc.creatorSklená?ová, Hana
dc.creatorSkrlíková, Jana
dc.creatorSrámková, Ivana
dc.creatorAndruch, Vasil
dc.creatorBalogh, Ioseph S.
dc.creatorSolich, Petr
dc.date.accessioned2018-11-07T20:08:37Z
dc.date.accessioned2022-10-15T01:50:44Z
dc.date.available2018-11-07T20:08:37Z
dc.date.available2022-10-15T01:50:44Z
dc.date.created2018-11-07T20:08:37Z
dc.date.issued2012-07
dc.identifierAcebal, Carolina Cecilia; Sklená?ová, Hana; Skrlíková, Jana; Srámková, Ivana; Andruch, Vasil; et al.; Application of DV-SIA manifold for determination of thiocyanate ions in human saliva samples; Elsevier Science; Talanta; 96; 7-2012; 107-112
dc.identifier0039-9140
dc.identifierhttp://hdl.handle.net/11336/63933
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4331997
dc.description.abstractAn automated, simple and inexpensive double-valve sequential injection analysis (DV-SIA) spectrophotometic method with online liquid-liquid extraction, for the determination of thiocyanate has been developed. The method has been based on the formation of an ion associate between thiocyanate and Astra Phloxine in acidic medium, and the subsequent extraction with amylacetate. The absorbance of the extracted ion associate was measured at 550 nm. The calibration function was linear in the range 0.05-0.50 mmol L-1 and the regression equation was A = (1.887 ± 0.053) [SCN- mmol L-1] + (0.037 ± 0.014) with a correlation coefficient of 0.995. The precision of the proposed method was evaluated by the relative standard deviation (RSD) values at two concentration levels: 0.20 and 0.50 mmol L-1. The obtained results were 1.0 and 2.8%, respectively, for the intra-day precision, and 4.2 and 3.8%, respectively for the inter-day precision. The calculated detection limit was 0.02 mmol L-1. The developed method has been successfully applied for determining thiocyanate ions in human saliva samples. © 2012 Elsevier B.V. All rights reserved.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.talanta.2012.01.021
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0039914012000276
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBIOLOGICAL SAMPLES
dc.subjectDV-SIA
dc.subjectEXTRACTION
dc.subjectTHIOCYANATE
dc.titleApplication of DV-SIA manifold for determination of thiocyanate ions in human saliva samples
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución