dc.creatorPadro, Julian
dc.creatorOsorio Grisales, Jaiver
dc.creatorArancibia, Juan Alberto
dc.creatorOlivieri, Alejandro Cesar
dc.creatorCastells, Cecilia Beatriz Marta
dc.date.accessioned2022-07-16T02:37:22Z
dc.date.accessioned2022-10-15T01:29:43Z
dc.date.available2022-07-16T02:37:22Z
dc.date.available2022-10-15T01:29:43Z
dc.date.created2022-07-16T02:37:22Z
dc.date.issued2016-05
dc.identifierPadro, Julian; Osorio Grisales, Jaiver; Arancibia, Juan Alberto; Olivieri, Alejandro Cesar; Castells, Cecilia Beatriz Marta; Enantiomeric analysis of overlapped chromatographic profiles in the presence of interferences. Determination of ibuprofen in a pharmaceutical formulation containing homatropine; Elsevier Science; Journal of Chromatography - A; 1467; 5-2016; 255-260
dc.identifier0021-9673
dc.identifierhttp://hdl.handle.net/11336/162268
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4330067
dc.description.abstractIn this work, we studied the combination of chemometric methods with chromatographic separations as a strategy applied to the analysis of enantiomers when complete enantioseparation is difficult or requires long analysis times and, in addition, the target signals have interference from the matrix. We present the determination of ibuprofen enantiomers in pharmaceutical formulations containing homatropine as interference by chiral HPLC-DAD detection in combination with partial least-squares algorithms. The method has been applied to samples containing enantiomeric ratios from 95:5 to 99.5:0.5 and coelution of interferents. The results were validated using univariate calibration and without homatropine. Relative error of the method was less than 4.0%, for both enantiomers. Limits of detection (LOD) and quantification (LOQ) for (S)-(+)-ibuprofen were 4.96 × 10−10 and 1.50 × 10−9 mol, respectively. LOD and LOQ for the R-(−)-ibuprofen were LOD = 1.60 × 10−11 mol and LOQ = 4.85 × 10−11 mol, respectively. Finally, the chemometric method was applied to the determination of enantiomeric purity of commercial pharmaceuticals. The ultimate goal of this research was the development of rapid, reliable, and robust methods for assessing enantiomeric purity by conventional diode array detector assisted by chemometric tools.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.chroma.2016.05.094
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S002196731630718X
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCHIRAL ANALYSIS
dc.subjectIBUPROFEN ENANTIOMERIC PURITY
dc.subjectINTERFERENCES
dc.subjectLIQUID CHROMATOGRAPHY
dc.subjectMULTIVARIATE CALIBRATION
dc.titleEnantiomeric analysis of overlapped chromatographic profiles in the presence of interferences. Determination of ibuprofen in a pharmaceutical formulation containing homatropine
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución