dc.creatorMessina, Germán Alejandro
dc.creatorPanini, Nancy Veronica
dc.creatorMartinez, Noelia Anabel
dc.creatorRaba, Julio
dc.date.accessioned2020-01-03T23:26:36Z
dc.date.accessioned2022-10-15T01:00:52Z
dc.date.available2020-01-03T23:26:36Z
dc.date.available2022-10-15T01:00:52Z
dc.date.created2020-01-03T23:26:36Z
dc.date.issued2008-09
dc.identifierMessina, Germán Alejandro; Panini, Nancy Veronica; Martinez, Noelia Anabel; Raba, Julio; Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples; Academic Press Inc Elsevier Science; Analytical Biochemistry; 380; 2; 9-2008; 262-267
dc.identifier0003-2697
dc.identifierhttp://hdl.handle.net/11336/93549
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4327717
dc.description.abstractInterleukin-6 (IL-6), an inflammatory cytokine, is one of the most important mediators of fever, the acute phase response, and inflammatory conditions. Described here is an integrated microfluidic immunosensor capable of detecting the concentration of IL-6 in human serum samples by use of an electrochemical method in a microfluidic biochip format. The detection of IL-6 was carried out using a sandwich immunoassay method based on the use of anti-IL-6 monoclonal antibodies, immobilized on a 3-aminopropyl-modified controlled-pore glass (APCPG) packet in a central channel (CC) of the microfluidic system. The IL-6 in the serum sample is allowed to react immunologically with the immobilized anti-IL-6 and biotin-labeled second antibodies specific to IL-6. After washing, the streptavidin-alkaline phosphatase conjugate is added. p-Aminophenyl phosphate is converted to p-aminophenol by alkaline phosphatase, and the electroactive product is quantified on a gold electrode at 0.10 V. For electrochemical detection and enzyme immunoassay, the LOD was 0.41 and 1.56 pg mL-1, respectively. Reproducibility assays employed repetitive standards of IL-6, and the intra- and inter-assay coefficients of variation were below 6.5%. Compared with the traditional IL-6 sensing method, the integrated microfluidic immunosensor required smaller amounts of sample to perform faster detection.
dc.languageeng
dc.publisherAcademic Press Inc Elsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.ab.2008.05.055
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003269708003679
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectALKALINE PHOSPHATASE
dc.subjectAMPEROMETRIC IMMUNOSENSOR
dc.subjectENZYME IMMUNOASSAYS
dc.subjectFLOW INJECTION ANALYSIS
dc.subjectINTERLEUKIN-6
dc.subjectMICROFLUIDIC
dc.titleMicrofluidic immunosensor design for the quantification of interleukin-6 in human serum samples
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución