Wedge cells for refractometry: materials and parameters selection criteria

dc.creatorVázquez, Patricia María Elena
dc.creatorOreglia, Eduardo Victor
dc.creatorCiocci Brazzano, Ligia
dc.creatorVeiras, Francisco Ezequiel
dc.creatorMatteo, Claudia Leda
dc.creatorSorichetti, Patricio Aníbal
dc.date.accessioned2022-09-16T15:06:13Z
dc.date.accessioned2022-10-15T00:43:53Z
dc.date.available2022-09-16T15:06:13Z
dc.date.available2022-10-15T00:43:53Z
dc.date.created2022-09-16T15:06:13Z
dc.date.issued2020-06
dc.identifierVázquez, Patricia María Elena; Oreglia, Eduardo Victor; Ciocci Brazzano, Ligia; Veiras, Francisco Ezequiel; Matteo, Claudia Leda; et al.; Celdas en cuña para refractometría: criterios de selección de materiales y parámetros; Universidad de Buenos Aires. Facultad de Ingeniería; Elektron; 4; 1; 6-2020; 8-13
dc.identifierhttp://hdl.handle.net/11336/169106
dc.identifier2525-0159
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4326167
dc.description.abstractEste trabajo presenta criterios de selección de materiales y parámetros de celdas en cuña para refractometría en el rango visible. Estas celdas consisten en dos prismas de ángulo recto enfrentados, que definen una cavidad con forma de cuña entre ellas, en la que se coloca la muestra cuyo índice de refracción se desea medir. Éste se determina a partir de la desviación de un haz luminoso que atraviesa la celda. Este modelo para fines de ingeniería tiene en cuenta la geometría de la celda y los índices de refracción del material de la celda y de la muestra. A partir de allí realizamos el cálculo numérico y trazado de rayos correspondiente al sistema óptico. También proponemos ajustes polinómicos para simplificar el tratamiento numérico, como complemento de las ecuaciones completas. Estos polinomios dan el índice de refracción de la muestra como una función explícita del ángulo de deflexión. Se incluye además el análisis de los errores de la aproximación.
dc.description.abstractThis work presents the materials and parameters selection criteria of wedge cells for refractometry in the visible range. These cells consist of two right angle prisms facing each other, defining a wedge-shaped cavity where the sample is placed. The refractive index of the sample is determined from the deviation of a light beam that traverses the cell. This model for engineering purposes includes the cell geometry and the refractive indexes of the cell material and the sample. We perform the numerical calculation and ray tracing of the optical system. We also propose polinomial fitting functions in order to simplify the numerical treatment, and as a complement to the complete set of equations. These polynomials give the refractive index of the sample as an explicit function of the deviation angle. An analysis of the approximation errors is also given.
dc.languagespa
dc.publisherUniversidad de Buenos Aires. Facultad de Ingeniería
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://elektron.fi.uba.ar/index.php/elektron/article/view/85
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.37537/rev.elektron.4.1.85.2020
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectINTRUMENTACIÓN ÓPTICA
dc.subjectREFRACTOMETRÍA
dc.subjectMETROLOGÍA
dc.titleCeldas en cuña para refractometría: criterios de selección de materiales y parámetros
dc.titleWedge cells for refractometry: materials and parameters selection criteria
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución