dc.creatorBrites, Carlos D.S.
dc.creatorMartínez, Eduardo David
dc.creatorUrbano, Ricardo R.
dc.creatorRettori, Carlos
dc.creatorCarlos, Luís D.
dc.date.accessioned2021-01-26T14:44:46Z
dc.date.accessioned2022-10-14T21:44:18Z
dc.date.available2021-01-26T14:44:46Z
dc.date.available2022-10-14T21:44:18Z
dc.date.created2021-01-26T14:44:46Z
dc.date.issued2019-04
dc.identifierBrites, Carlos D.S.; Martínez, Eduardo David; Urbano, Ricardo R.; Rettori, Carlos; Carlos, Luís D.; Self-calibrated double luminescent thermometers through upconverting nanoparticles; Frontiers Media S.A.; Frontiers in Chemistry; 7; APR; 4-2019; 1-10
dc.identifier2296-2646
dc.identifierhttp://hdl.handle.net/11336/123737
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4310083
dc.description.abstractLuminescent nanothermometry uses the light emission from nanostructures for temperature measuring. Non-contact temperature readout opens new possibilities of tracking thermal flows at the sub-micrometer spatial scale, that are altering our understanding of heat-transfer phenomena occurring at living cells, micro electromagnetic machines or integrated electronic circuits, bringing also challenges of calibrating the luminescent nanoparticles for covering diverse temperature ranges. In this work, we report self-calibrated double luminescent thermometers, embedding in a poly(methyl methacrylate) film Er 3+ - and Tm 3+ -doped upconverting nanoparticles. The Er 3+ -based primary thermometer uses the ratio between the integrated intensities of the 2 H 11 /2→4I 15/2 and 4 S 3 /2→4I 15/2 transitions (that follows the Boltzmann equation) to determine the temperature. It is used to calibrate the Tm 3+ /Er 3+ secondary thermometer, which is based on the ratio between the integrated intensities of the 1 G4→3H 6 (Tm 3+ ) and the 4 S 3 /2→4I 15/2 (Er 3+ ) transitions, displaying a maximum relative sensitivity of 2.96% K -1 and a minimum temperature uncertainty of 0.07 K. As the Tm 3+ /Er 3+ ratio is calibrated trough the primary thermometer it avoids recurrent calibration procedures whenever the system operates in new experimental conditions.
dc.languageeng
dc.publisherFrontiers Media S.A.
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3389/fchem.2019.00267
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.frontiersin.org/articles/10.3389/fchem.2019.00267/full
dc.rightshttps://creativecommons.org/licenses/by/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDOUBLE THERMOMETERS
dc.subjectLUMINESCENCE
dc.subjectPOLYMER NANOCOMPOSITES
dc.subjectPRIMARY THERMOMETRY
dc.subjectSELF-REFERENCED THERMOMETRY
dc.subjectUPCONVERTING NANOPARTICLES
dc.titleSelf-calibrated double luminescent thermometers through upconverting nanoparticles
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución