dc.creatorMedawar Aguilar, Victoria
dc.creatorMessina, Germán Alejandro
dc.creatorFernández Baldo, Martín Alejandro
dc.creatorRaba, Julio
dc.creatorPereira, Sirley Vanesa
dc.date.accessioned2018-11-20T17:48:43Z
dc.date.accessioned2022-10-14T21:37:24Z
dc.date.available2018-11-20T17:48:43Z
dc.date.available2022-10-14T21:37:24Z
dc.date.created2018-11-20T17:48:43Z
dc.date.issued2017-01
dc.identifierMedawar Aguilar, Victoria; Messina, Germán Alejandro; Fernández Baldo, Martín Alejandro; Raba, Julio; Pereira, Sirley Vanesa; Fluorescent immunosensor using AP-SNs and QDs for quantitation of IgG anti-Toxocara canis; Elsevier Science; Microchemical Journal; 130; 1-2017; 436-441
dc.identifier0026-265X
dc.identifierhttp://hdl.handle.net/11336/64763
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4309446
dc.description.abstractThe objective of this work was to develop a microfluidic immunosensor for the quantitative determination of IgG antibodies to Toxocara canis (IgG anti-T.canis), causal agent of toxocariasis. This disease is caused by accidental ingestion of infective eggs that hatch into the first portion of the intestine. Subsequently, the juvenile stages are distributed throughout the body, generating symptoms from mild to severe manifestations. The possibility of early diagnosis is of great importance, allowing proper management and treatment of patients suffering from toxocariasis. IgG anti-T.canis antibodies detection was carried out using a non-competitive immunoassay, in which excretory-secretory antigens from T. canis second-stage larvae (TES) were covalently immobilized on 3-aminopropyl-functionalized silica-nanoparticles (AP-SNs). Antibodies present in serum samples immunologically reacted with TES and then were quantified by using a second antibody labeled with cadmium selenide zinc sulfide quantum dots (CdSe-ZnS QDs). The concentration of IgG anti-T. canis antibodies present in the serum sample was measured by LIF detector, using excitation lambda at 491 nm and emission at 540 nm. The total assay time was 30 minutes, having made LIF detection in less than 1 minute. The detection limit calculated for the proposed methodology was 0.12 ng mL-1 and the coefficients of intra- and inter-assay variation were less than 6%. The results show the usefulness of the developed immunosensor for the fast determination of IgG antibodies anti T. canis.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2016.10.027
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectTOXOCARA
dc.subjectMICROFLUIDIC IMMUNOSENSOR
dc.subjectLASER INDUCED FLUORESCENCE
dc.subjectQUANTUMDOT
dc.subjectSILICA PARTICLE
dc.titleFluorescent immunosensor using AP-SNs and QDs for quantitation of IgG anti-Toxocara canis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución