dc.contributorLabas, Marisol Daniela
dc.contributorGarcía, Guillermos Manuel
dc.contributorMussati, Miguel Ceferino
dc.contributorPanigatti, María Cecilia
dc.contributorBrandi, Rodolfo Juan
dc.creatorCristiani, Mariana
dc.date.accessionedinfo:eu-repo/date/embargoEnd/2022-12-11
dc.date.accessioned2022-10-14T17:47:08Z
dc.date.availableinfo:eu-repo/date/embargoEnd/2022-12-11
dc.date.available2022-10-14T17:47:08Z
dc.date.createdinfo:eu-repo/date/embargoEnd/2022-12-11
dc.date.issued2020-03-10
dc.identifierhttps://hdl.handle.net/11185/5711
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4264268
dc.description.abstractEn este trabajo de Tesis Doctoral se estudió la aplicación de radiación UV, APA y su combinacion, como tecnologías eficientes y sustentables para la desinfección de agua. Para ello se realizaron ensayos en un reactor a escala de laboratorio con agua contaminada con E. coli y P. aeruginosa, se controló la viabilidad de las mismas mediante siembra en placas de agar selectivos y diferenciales. Como aspecto novedoso de este trabajo se utilizó la técnica de ERIC-PCR para analizar modificaciones en el ADN bacteriano. Los ensayos realizados permitieron cuantificar el daño en forma específica y asociada directamente al fenómeno de muerte celular. Debido a esto, pudimos desarrollar una descripción cuantitativa que detalla tanto lo que sucede a nivel global (inactivación de la población microbiana) como a nivel de daño al ADN (técnica de PCR), cuando son aplicados dos desinfectantes con diferentes targets moleculares.
dc.description.abstractn this doctorate thesis we evaluated the combined and individual application of APA and UV as efficient and sustainable tools for water disinfection. Disinfection essays on water contaminated with E. coli and P. aeruginosa were performed in a laboratory-scale reactor and the viability of these microorganisms was controlled by seeding on selective and differential agar media. We used ERIC-PCR to analyze the modifications present in the bacterial DNA, which constitutes a novel application of this technique. We were able to quantify the damage on the bacterial DNA and to directly correlate DNA damage with the bacterial death. Consequently, we developed a quantitative description that details both the changes occurring at a global level (inactivation of the populations of microorganisms) and at the DNA level (assessed by PCR), when two disinfectants with different molecular targets are used.
dc.languagespa
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.subjectDisinfection
dc.subjectEscherichia coli
dc.subjectPseudomonas aeruginosa
dc.subjectDNA
dc.subjectERIC-PCR
dc.subjectDamage
dc.subjectDesinfeccion
dc.subjectEscherichia coli
dc.subjectPseudomonas aeruginosa
dc.subjectADN
dc.subjectERIC-PCR
dc.subjectDaño
dc.titleEstudio cinético de la desinfección de aguas utilizando agentes oxidantes en combinación con radiación UV basado en el análisis del daño celular con técnicas de biología molecular
dc.typeinfo:eu-repo/semantics/doctoralThesis
dc.typeinfo:ar-repo/semantics/tesis doctoral
dc.typeinfo:eu-repo/semantics/acceptedVersion
dc.typeSNRD


Este ítem pertenece a la siguiente institución