dc.contributorLeón Álvarez, Alejandro
dc.creatorZuluaga Giraldo, Jhonathan Steeven
dc.creatorRodríguez Ibagué, Daniel Alejandro
dc.creatorOrtiz Cruz, Juan Diego
dc.date2022-01-01T08:00:00Z
dc.date.accessioned2022-10-13T16:01:56Z
dc.date.available2022-10-13T16:01:56Z
dc.identifierhttps://ciencia.lasalle.edu.co/optometria/1918
dc.identifierhttps://ciencia.lasalle.edu.co/cgi/viewcontent.cgi?article=2923&context=optometria
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4190891
dc.description<p>La retinoscopía es una técnica objetiva la cual permite evaluar el estado refractivo del paciente; la retinoscopía dinámica monocular de Merchán fue diseñada por Gabriel Merchán con el fin de ser empleada como alternativa de la retinoscopía bajo cicloplejia. Objetivo. Comparar los resultados obtenidos al realizar la retinoscopía dinámica monocular de Merchán (RDM) y la retinoscopía bajo cicloplejia con ciclopentolato al 1% en adolescentes y adultos jóvenes. Metodología. Se realizó un estudio descriptivo, transversal de una prueba clínica, evaluando 20 pacientes (40 ojos) de manera aleatoria entre los dieciocho y los treinta años, los cuales cumplieron los criterios de inclusión; se evaluó el estado refractivo mediante las siguientes técnicas: RDM, retinoscopía bajo cicloplejia, retinoscopía estática y refracción subjetiva; todos los pacientes se encontraban bajo las mismas condiciones y se examinaron con los mismos equipos para evitar variaciones. Resultados. La confiabilidad mostró ser buena para el equivalente esférico con la retinoscopía estática, el subjetivo y la retinoscopía de Merchán, aunque el coeficiente de repetitividad para este vector fue pobre. De igual manera, aunque el coeficiente de concordancia entre la retinoscopía monocular de Merchán y la retinoscopía bajo cicloplejia es bueno, el coeficiente de acuerdo entre ambas técnicas demostró una diferencia igual a 1.50 D. Conclusión. La retinoscopía monocular de Merchán no demostró ser una técnica confiable en la cuantificación del defecto refractivo al ser comparada con la retinoscopía bajo cicloplejia.</p>
dc.descriptionRetinoscopy is an objective technique which allows evaluating the patient's refractive status; Merchàn's monocular dynamic retinoscopy was designed by Gabriel Merchán in order to be used as an alternative to retinoscopy under cycloplegia. Goal. To compare the results obtained when performing Merchán monocular dynamic retinoscopy and retinoscopy under cycloplegia with 1% cyclopentolate in adolescents and young adults. Methodology. A descriptive, cross-sectional study of a clinical trial was carried out where 20 patients (40 eyes) were randomly evaluated between the ages of eighteen and thirty, who met the inclusion criteria; The refractive status was evaluated using the following techniques: RDM, retinoscopy under cycloplegia, static retinoscopy and subjective refraction; all patients were under the same conditions and were examined with the same equipment to avoid variations. Results. Reliability was shown to be good for the spherical equivalent with static retinoscopy, subjective retinoscopy, and Merchán retinoscopy, although the repeatability coefficient for this vector was poor. Similarly, although the coefficient of agreement between monocular Merchán retinoscopy and retinoscopy under cycloplegia is good, the coefficient of agreement between both techniques showed a difference equal to 1.50 D. Conclusion. Merchán's monocular retinoscopy did not prove to be a reliable technique in quantifying the refractive error when compared with retinoscopy under cycloplegia.
dc.languagespa
dc.publisherUniversidad de La Salle. Facultad de Ciencias de la Salud. Optometría
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsacceso abierto
dc.subjectAcomodación tónica
dc.subjectCuantificación del estado refractivo
dc.subjectRetinoscopía dinámica monocular de Merchán
dc.subjectRetinoscopía bajo cicloplejia
dc.titleComparación entre la Retinoscopía de Merchán y la Retinoscopía bajo cicloplejia en jóvenes de 18 a 30 años de la Universidad de la Salle sede Chapinero en la ciudad de Bogotá
dc.typeTrabajo de grado - Pregrado
dc.typeOptometry
dc.thesisOptometría


Este ítem pertenece a la siguiente institución