dc.description<p>Con el fin de determinar la calidad microbiológica del aire presente en los baños, corredores, recepción y almacén de la Clínica de Optometría de la Universidad de La Salle se llevó a cabo un muestreo de aire, además de mediciones de porcentaje de humedad relativa y velocidad del viento durante dos semanas. Lo cual permitió determinar 27 morfotipos, de los cuales se identificaron 14 géneros bacterianos. El estudio encontró que hay una prevalencia de la presencia de bacterias además de una distribución más amplia teniendo en cuenta estudios previos. El viento y la humedad tienen una relación directa con el mantenimiento de géneros tales como: Staphylococcus (26.3%), Pantoea (10,5%) y Sphingomonas (5,3%) que son causantes de enfermedades oculares y zoonóticas, lo cual tiene un peligro potencial para la salud de aquellos que asisten regularmente a las instalaciones de la Clínica. De igual manera se identificó que el 64% de las secciones de muestreo están sobre el límite establecido por la ISO 14644 de UFC para zonas limpias</p>
dc.descriptionIn order to determine the microbiological quality of the air present in the bathrooms, corridors, reception and storage of the Optometry Clinic of the University of La Salle, air sampling was carried out, as well as relative humidity and velocity percentage measurements of the wind for two weeks. This allowed the determination of 27 morphotypes, of which 14 bacterial genera were identified. The study found that there is a prevalence of the presence of bacteria in addition to a wider distribution taking into account previous studies. The wind and humidity have a direct relationship with the maintenance of genera such as: Staphylococcus (26.3%), Pantoea (10.5%) and Sphingomonas (5.3%) that are responsible for eye and zoonotic diseases, which has a potential danger to the health of those who regularly attend the facilities of the Clinic. Likewise, it was identified that 64% of the sampling sections are above the limit established by the ISO 14644 of UFC for clean areas
dc.languagespa
dc.publisherUniversidad de La Salle. Facultad de Ingeniería. Ingeniería Ambiental y Sanitaria
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsacceso abierto
dc.subjectBioaerosoles
dc.subjectCalidad del aire intramural
dc.subjectClínica de optometría
dc.subjectSalud ambiental
dc.subjectIntramural air quality
dc.subjectClinical optometry
dc.subjectEnvironmental health
dc.subjectCalidad del aire
dc.subjectAire - Purificación
dc.subjectAire - Análisis
dc.subjectContaminación del aire
dc.subjectAir quality
dc.subjectWater - Purification
dc.subjectAir - Analysis
dc.subjectAir - Pollution
dc.titleEvaluación de la calidad microbiológica del aire en la Clínica de Optometría de La Universidad de La Salle
dc.typeTrabajo de grado - Pregrado
dc.thesisIngeniería Ambiental y Sanitaria


Este ítem pertenece a la siguiente institución