Colombia
| Trabajo de grado - Pregrado
Diseño de un sistema de control de la contaminación del aire para la Escuela Tecnológica Instituto Técnico Central de Bogotá
dc.contributor | Herrera Torres, Gabriel | |
dc.creator | Iglesias Hueso, Laura Andrea Isabel | |
dc.date | 2018-01-01T08:00:00Z | |
dc.date.accessioned | 2022-10-13T14:04:17Z | |
dc.date.available | 2022-10-13T14:04:17Z | |
dc.identifier | https://ciencia.lasalle.edu.co/ing_ambiental_sanitaria/772 | |
dc.identifier | https://ciencia.lasalle.edu.co/cgi/viewcontent.cgi?article=1771&context=ing_ambiental_sanitaria | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4163933 | |
dc.description | <p>El presente proyecto se realizó con el fin de diseñar el sistema de control para la contaminación del aire para la Escuela Tecnológica Instituto Técnico Central, específicamente para los talleres de Mecánica Industrial, Metalistería, Modelería, Fundición y áreas académicas colindantes, con el propósito de evitar o reducir los riesgos a los que estén expuestos sus estudiantes y trabajadores en el desarrollo de sus actividades diarias. Para ello, se realizó un diagnóstico del lugar de estudio, se valoraron riesgos, se evaluaron los niveles de contaminación del aire interior por material particulado, ruido, iluminación y estrés térmico, y se diseñaron medidas de control para las áreas en las que se superaban los valores límite permisibles. Los resultados de la evaluación de factores de riesgo se compararon con la resolución 2400 de 1979, obteniendo para iluminación y estrés térmico valores inferiores al valor límite permisible establecido por la legislación. En cuanto a ruido, se obtuvo un nivel de presión sonora de 91.85 dB y 86.39 dB en el taller de Modelería y de 87.68 dB en el taller de Mecánica, cuando la normatividad establece un valor de 85 dB, a partir de lo cual, se propusieron medidas correctivas sobre el ambiente y el trabajador. En lo que respecta a material particulado, se encontró que las mediciones en el taller de Modelería superaban el valor límite permisible de 1 mg/m3 hasta con un resultado de 5.43 mg/m3, lo cual demandó el diseño de medidas de control que redujeran las concentraciones de polvo de madera, a través del uso de elementos de protección personal y la propuesta de un sistema de ventilación</p> | |
dc.description | The present project was conducted in order to design the control system for indoor air pollution for the Escuela Tecnológica Instituto Técnico Central, specifically for workshops of Industrial Mechanic, Metalwork, Modeleria, Foundry and surrounding academic areas, with the purpose of avoiding or reducing the risks to which students and employees are exposed in the development of their daily activities. For it, a diagnostic of the study site was conducted, risks and levels of indoor air pollution by particulate matter, noise, lighting and thermal stress were assessed, and control measurements were designed for areas where emissions were higher than threshold limit values. Assessment results of risks factors were compared with resolution 2400 of 1979, obtaining for lighting and thermal stress values below the threshold limit value established by legislation. According to noise, it was obtained a sound pressure level of 91.85 dB and 86.39 dB at Modeleria’s workshop and 87.68 dB at Industrial Mechanic’s workshop, when normativity establishes a value of 85 dB, from which it was proposed corrective measures on the environment and the employee. Meanwhile, for particulate matter, it was found that measurements at Modeleria’s workshop exceeded the threshold limit value of 1 mg/m3 even with a result of 5.43 mg/m3, which required design of control measurements that reduce wood dust concentrations through the use of personal protective elements and the proposal for a ventilation system | |
dc.language | spa | |
dc.publisher | Universidad de La Salle. Facultad de Ingeniería. Ingeniería Ambiental y Sanitaria | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.rights | acceso abierto | |
dc.subject | Sistema de control | |
dc.subject | Contaminación del aire en interiores | |
dc.subject | Salud y seguridad en el trabajo | |
dc.subject | Factores de riesgo físico | |
dc.subject | Material particulado | |
dc.subject | Control system | |
dc.subject | Indoor air pollution | |
dc.subject | Occupational safety and health | |
dc.subject | Physical risk factors | |
dc.subject | Particulate matter | |
dc.subject | Contaminación del aire - Mediciones | |
dc.subject | Aire - Análisis | |
dc.subject | Saneamiento ambiental | |
dc.subject | Calidad del aire | |
dc.subject | Contaminación del aire - Mediciones | |
dc.subject | Air - Analysis | |
dc.subject | Environmental health | |
dc.subject | Air quality | |
dc.title | Diseño de un sistema de control de la contaminación del aire para la Escuela Tecnológica Instituto Técnico Central de Bogotá | |
dc.type | Trabajo de grado - Pregrado | |
dc.thesis | Ingeniería Ambiental y Sanitaria |