dc.creatorRodríguez Álvarez, Martha Fabiola
dc.creatorAlfonso Elizalde, Laura Lizeth
dc.creatorNariño Roa, Paola Andrea
dc.date17 de enero de 2014
dc.date21 de marzo de 2014
dc.date2014-01-01T08:00:00Z
dc.date.accessioned2022-10-13T13:42:01Z
dc.date.available2022-10-13T13:42:01Z
dc.identifierhttps://ciencia.lasalle.edu.co/svo/vol12/iss1/9
dc.identifierhttps://ciencia.lasalle.edu.co/cgi/viewcontent.cgi?article=1273&context=svo
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4159120
dc.description<em><strong>Objetivo:</strong></em> evaluar la repetibilidad y reproducibilidad de las medidas del espesor y curvatura corneal obtenidas con el Oculus Pentacam, de la Universidad de La Salle. <em><strong>Materiales y métodos:</strong></em> para la repetibilidad de las medidas de la curvatura y espesor corneal con el Pentacam, un solo observador realizó diez repeticiones de diez ojos, y para la reproducibilidad dos examinadores, en sesiones separadas, ejecutaron tres tomas consecutivas en ambos ojos de veinte sujetos sanos. <em><strong>Resultados:</strong></em> en repetibilidad, el coeficiente de variación de las medidas de la curvatura corneal se encontró entre 0,2 % y 0,4 % y en el caso del espesor corneal varió entre 0,7 % y 1,4 %. El coeficiente de variación interobservador, para la curvatura corneal estuvo entre 3,6 % y 4,0 %, y para el espesor corneal entre 4,9 % y 7,9 %. No se hallaron diferencias estadísticas (p &gt; 0,05) ni clínicamente significativas entre las observaciones inter e intraobservador. El coeficiente de correlación interobservador fue mayor al 0,90 (p &lt; 0,01). <em><strong>Conclusión:</strong></em> las medidas de la curvatura y espesor corneal obtenidas con el Oculus Pentacam son confiables, reproducibles y repetibles.
dc.description<em><strong>Objective:</strong></em> To evaluate the repeatability and reproducibility of the measurements of corneal thickness and curvature obtained with the Oculus Pentacam of the University of La Salle. Materials and <em><strong>Methods:</strong></em> For the repeatability of the measurements of corneal curvature and thickness with the Pentacam, a single observer performed ten repetitions of ten eyes, and for reproducibility, two examiners executed, in separate sessions, three consecutive shots in both eyes of twenty healthy subjects. <em><strong>Results:</strong></em> As for reproducibility, the coefficient of variation of the measurements of corneal curvature was found to be between 0.2% and 0.4%, and in case of corneal thickness, it varied between 0.7% and 1.4%. The coefficient of interobserver variation for corneal curvature was between 3.6% and 4.0%, and for corneal thickness, between 4.9% and 7.9%. There were no statistical (p> 0.05) nor clinically significant differences between inter and intraobserver observations. The interobserver correlation coefficient was higher than 0.90 (p < 0.01). <em><strong>Conclusion:</strong></em> The measurements of corneal curvature and thickness obtained with the Oculus Pentacam are reliable, reproducible and repeatable.
dc.formatapplication/pdf
dc.format11 - 19
dc.languagespa
dc.publisherUniversidad de La Salle. Ediciones Unisalle
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsAcceso abierto
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subjectreproducibilidad
dc.subjectrepetibilidad
dc.subjectcurvatura corneal
dc.subjectespesor corneal
dc.subjectOculus Pentacam
dc.subjectReproducibility, repeatability, corneal curvature, corneal thickness, Oculus Pentacam
dc.subjectEye Diseases
dc.subjectOptometry
dc.subjectOther Analytical, Diagnostic and Therapeutic Techniques and Equipment
dc.subjectVision Science
dc.titleRepetibilidad y reproducibilidad de las medidas del espesor y curvatura corneal obtenidas mediante el Oculus Pentacam
dc.typeArtículo de investigación
dc.identifier.doihttps://doi.org/10.19052/sv.2801
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
dc.type.contentText
dc.type.coarversionVersión publicada
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.relation.citationstartpage11
dc.relation.citationendpage19
dc.identifier.instnameinstname:Universidad de La Salle
dc.identifier.reponamereponame:Ciencia Unisalle
dc.identifier.repo.urlrepourl:https://ciencia.lasalle.edu.co/
dc.relation.ispartofcitationissue1
dc.relation.ispartofcitationvolume12
dc.relation.ispartofjournalCiencia y Tecnología para la Salud Visual y Ocular
dc.title.translatedRepeatability and reproducibility of the measurements of corneal thickness and curvature obtained with Oculus Pentacam