dc.descriptionTesis (Maestría en Ciencias, especialista en Hidrociencias).- Colegio de Postgraduados, 2013.
dc.descriptionEl objetivo de este trabajo fue desarrollar un sistema de adquisición de datos meteorológicos en tiempo real utilizando un controlador lógico programable (PLC) como una alternativa dentro de las estaciones meteorológicas comerciales. Para sensar la: temperatura del aire, humedad relativa, radiación solar, precipitación, velocidad y dirección del viento, se usaron sensores comerciales, durante el periodo comprendido entre el 23 de Mayo al 3 de Junio de 2013, para probar la estación, en la estación meteorológica del Colegio de Postgraduados Campus Montecillo. El sistema se compone de un PLC (modelo CX1020, marca Beckhoff), una Laptop donde se instaló una aplicación de monitoreo en tiempo real que se desarrolló en Visual Basic 2010 Express y la base de datos en MySQL para almacenar la información, que se puede usar para fines diversos. La interacción entre el PLC y la aplicación de monitoreo se realizó mediante comunicación inalámbrica Wi-Fi. Se usaron los programas TwinCAT System Manager (para la configuración del hardware) y TwinCAT PLC Control (para la programación del PLC). Se evaluó el funcionamiento del sistema al realizar comparaciones de las lecturas obtenidas de los sensores, contra instrumentos de referencia y sensores de una estación meteorológica Campbell Scientific. Los resultados indican que es factible el uso del PLC en la implementación de estaciones meteorológicas. _______________ ABSTRACT: The aim of this research was to develop a meteorological data acquisition system in real-time using a programmable logic controller (PLC) as an alternative to commercial weather stations. For sensing of: air temperature , relative humidity, solar radiation , rainfall, wind speed and direction, were used commercial sensors, during the period between May 23 to June 3 of 2013, to test the station, in the weather station of the Colegio de Postgraduados Campus Montecillo. The system consists of a PLC (CX1020 model, Beckhoff brand), a laptop where was installed an application of real-time monitoring that was developed in Visual Basic 2010 Express and the database in MySQL to store information, that can be used for different purposes. The interaction between the PLC and the monitoring application was implemented using wireless communication (Wi-Fi). Were used programs TwinCAT System Manager (Hardware configuration) and TwinCAT PLC Control (PLC programming). Was evaluated the system performance by making comparisons of the readings obtained of the sensors against reference instruments and sensors of a Campbell Scientific weather station. The results indicate that it is possible to use the PLC in the implementation of weather stations.
dc.languagespa
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.subjectEstaciones automáticas
dc.subjectMeteorología
dc.subjectSensores
dc.subjectTiempo real
dc.subjectAutomatic stations
dc.subjectMeteorology
dc.subjectSensors
dc.subjectReal time
dc.subjectHidrociencias
dc.subjectMaestría
dc.subjectinfo:eu-repo/classification/cti/6
dc.titleSistema de adquisición de datos meteorológicos en tiempo real
dc.typeinfo:eu-repo/semantics/masterThesis