dc.contributor | Callejas, Ivan Julio Apolonio | |
dc.contributor | http://lattes.cnpq.br/7395380953207614 | |
dc.contributor | Callejas, Ivan Julio Apolonio | |
dc.contributor | 622.632.771-53 | |
dc.contributor | http://lattes.cnpq.br/7395380953207614 | |
dc.contributor | Leão, Marlon | |
dc.contributor | 695.731.821-49 | |
dc.contributor | http://lattes.cnpq.br/8029228126244943 | |
dc.contributor | 622.632.771-53 | |
dc.contributor | Durante, Luciane Cleonice | |
dc.contributor | 474.810.131-87 | |
dc.contributor | http://lattes.cnpq.br/3288386869580332 | |
dc.contributor | Daltro, Adnauer Tarquínio | |
dc.contributor | 209.168.681-68 | |
dc.contributor | http://lattes.cnpq.br/3181697735110316 | |
dc.date.accessioned | 2016-09-03 | |
dc.date.accessioned | 2021-07-20T14:43:10Z | |
dc.date.accessioned | 2022-10-12T18:18:19Z | |
dc.date.available | 2016-09-03 | |
dc.date.available | 2021-07-20T14:43:10Z | |
dc.date.available | 2022-10-12T18:18:19Z | |
dc.date.created | 2016-09-03 | |
dc.date.created | 2021-07-20T14:43:10Z | |
dc.date.issued | 2016-08-05 | |
dc.identifier | NOGUEIRA, Jocely Rosanna da Silva. Desempenho de painel de vedação vertical externa em Steel Framing composto por placas de madeira mineralizada. 2016. 145 f. Dissertação (Mestrado em Engenharia de Edificações e Ambiental) - Universidade Federal de Mato Grosso, Faculdade de Arquitetura, Engenharia e Tecnologia, Cuiabá, 2016. | |
dc.identifier | http://ri.ufmt.br/handle/1/2630 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4094036 | |
dc.description.abstract | The design panel designs for vertical seal to consider the user performance requirements is a
challenge, given the need to reconcile the service to various criteria established normatively.
In addition to the prescriptive rules, from 2013 became effective the performance standards of
housing Building, according to NBR 15575. In this scenario, industrialized fence panels may
offer some advantage to meet these new requirements, as well as being standardized and
Quick implementation, have flexibility in the choice of materials for its composition and can
thus be devised to meet the performance levels of internal and external vertical sealing system
(SVVIE). In this sense, this research aimed to determine the level of thermal and structural
performance, vertical fence panel structured Light Steel Framing and made externally by
cement and wood plate mineralized and internally by plasterboard, designed for residential
buildings. For structural performance analysis they were built specimens, simulating the seal
in use, in order to evaluate the loads of occupation and impacts from accidental shocks and
normal use of the building. Hard body tests, loads from suspended parts and soft body were
performed. For thermal performance analysis, two methods were used, with the simple
calculation, to determine the transmittance and the theoretical thermal capacity of panel and
the method for protected hot box test, where through the samples in reduced size, was
performed to characterize the proposed panel, following the procedures established by NBR
15575. evaluations of the panel indicated service user requirements for stability and security,
from the use and occupation of the building, supporting actions of impact, vibration, loading
the media suspended parts, resulting from normal use of the building. Performance levels
recorded in the structural tests have shown compliance with the performance level Low (M).
Regarding the thermal performance of the panel transmittance, capacity and theoretical panel
thermal lag were equal to 2.00 W / m2K, 40.29 kJ / (m2.K) and 1,87h, not meeting the
regulatory requirements of capacity Thermal and the thermal delay, not being this way, the
panel likely to be classified as to the performance, this criterion can be determined by means
of computer simulation. The thermal transmittance of the test panel, scaled-down was
determined getting average value of 1.93 W / m2K, with a confidence interval between 1.77
and 2.08 W / m2K, confirming the theoretical value found in the search. The difference found
is given because of the theoretical thermal conductivity properties of the components of the
panels are different than those available on the market, as well as the environmental
conditions of the test and the uncertainty of the individual measurements from sensors. It
follows then that the panel has adequate structural performance, and the thermal performance
of the panel should be evaluated by means of computer simulation in each building typology
in which the panel is used in order to determine the level of thermal performance of the
building. | |
dc.publisher | Universidade Federal de Mato Grosso | |
dc.publisher | Brasil | |
dc.publisher | Faculdade de Arquitetura, Engenharia e Tecnologia (FAET) | |
dc.publisher | UFMT CUC - Cuiabá | |
dc.publisher | Programa de Pós-Graduação em Engenharia de Edificações e Ambiental | |
dc.rights | Acesso Aberto | |
dc.title | Desempenho de painel de vedação vertical externa em Steel Framing composto por placas de madeira mineralizada | |
dc.type | Tesis | |