dc.contributorPaulo Roberto Savassi Rocha
dc.contributorhttp://lattes.cnpq.br/4073486641496824
dc.creatorOrlando Barreto Zocratto
dc.date.accessioned2022-09-30T13:09:23Z
dc.date.accessioned2022-10-10T23:53:26Z
dc.date.available2022-09-30T13:09:23Z
dc.date.available2022-10-10T23:53:26Z
dc.date.created2022-09-30T13:09:23Z
dc.date.issued2010-07-08
dc.identifierhttp://hdl.handle.net/1843/45786
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4047309
dc.description.abstractA fine needle aspiration citology (FNAC) has allowed a better selection of candidates for thyroidectomy providing a reduction in the number of operated patients and increased number of malignant tumors surgically resected. However, there is a wide variation in results, which may reflect differences in experience gained in its interpretation. It is believed that the efficiency of the method is directly related to training professional. The critical parameter of the clinical usefulness of a diagnostic test is its interobserver variability, and especially intraobserver. The objectives of this study was to evaluate the influence of the examiner's experience in the interpretation of cytological findings of thyroid and to correlate the cytologic findings issued by pathologists with and without experience, with the histological examinations of surgical specimens and to evaluate the influence of a broad definition of malignancy (BDM) instead of using the narrow definition of malignancy (NDM) on the calculations of measures and validation of diagnostic prediction. The results revealed consistent intraobserver reproducibility after the lapse of six months, both for the experienced pathologist (K = 0.82 [0.71 to 0.94], Kp = 0.79, p = 0.988) and for non-experienced (K = 0.78 [0.64 to 0.91], Kp = 0.71, p = 0.291). There was no difference for the inexperienced and experienced pathologist, respectively, in terms of rate: insufficient material (p = 0.72, p = 0.48), follicular neoplasm (FN) (p = 1.0, p = 0,09), falsepositive (p = 1.0, p = 0.72), false-negative using the NDM (p = 0.55, p = 0.60), false-negative using the BDM (p = 0.72, p = 0.72), proportion of malignant tumors identified using the NDM (p = 1.0, p = 0.59) and BDM (p = 1.0, p = 0,66). The analysis of interobserver reproducibility showed a significant difference in both the first moment (K = 0.55 [0.38 to 0.72], Kp = 0.50, p = 0.011) or the second afther six months (K = 0,54 [0.37 to 0.71], Kp = 0.44, p = 0.021). There was also a difference in the number of unsatisfactory results in both the first (p = 0.001) and second examination (p = 0.021), and FN in the second analysis (p = 0.015). However, no difference in the proportion of malignant tumors identified in the first (p = 0.79 [NDM], p = 0.81 [BDM]) and the second analysis (p = 0.78 [NDM], p = 0,50 [BDM]), as well as false-positive (p = 0.62, p = 0.21) and false-negative in the first analysis (p = 0.55 [NDM], p = 0.72 [BDM]) and the second analysis (p = 0.60 [NDM], p = 0.72 [BDM]). Conclude that the intraobserver reproducibility in the interpretation of FNA cytology is consistent and independent of experience to the survey, however, the interobserver reliability is influenced. The experience of the examiner influences significantly the proportion of unsatisfactory results and cases compatible with FN. The use of the NDM should be avoided when interpreting the case compatible with FN, in view of the high rate of malignancy observed in these samples, even when the reports are issued by experienced pathologists. Surgical indication of thyroid nodules should take into account the high rate of false-negative results observed at the FNAC, which occurs even when performed by experienced pathologist, as well as the high rate of unsatisfactory results, mainly due to the high rates of malignancy observed in these samples.
dc.publisherUniversidade Federal de Minas Gerais
dc.publisherBrasil
dc.publisherMEDICINA - FACULDADE DE MEDICINA
dc.publisherPrograma de Pós-Graduação em Medicina - Gastroenterologia
dc.publisherUFMG
dc.rightsAcesso Aberto
dc.subjectReprodutibilidade interexaminador e intraexaminador
dc.subjectExperiência
dc.subjectPunção aspirativa com agulha fina
dc.subjectNódulo tireoidiano
dc.titleEstudo citológico da glândula tireoide: comparação (intra e interexaminador) dos resultados com o exame histológico das peças cirúrgicas.
dc.typeTese


Este ítem pertenece a la siguiente institución