dc.contributorInoue, Roberto Santos
dc.contributorhttp://lattes.cnpq.br/6221209121565990
dc.contributorNogueira, Samuel Lourenço
dc.contributorhttp://lattes.cnpq.br/2287847504423307
dc.contributorhttp://lattes.cnpq.br/8787158005491236
dc.creatorDiegues, Daniel
dc.date.accessioned2022-04-07T17:38:08Z
dc.date.accessioned2022-10-10T21:39:19Z
dc.date.available2022-04-07T17:38:08Z
dc.date.available2022-10-10T21:39:19Z
dc.date.created2022-04-07T17:38:08Z
dc.date.issued2021-12-17
dc.identifierDIEGUES, Daniel. Método automático de calibração de IMU baseado no filtro de Kalman. 2021. Dissertação (Mestrado em Engenharia Elétrica) – Universidade Federal de São Carlos, São Carlos, 2021. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15823.
dc.identifierhttps://repositorio.ufscar.br/handle/ufscar/15823
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4045830
dc.description.abstractIMUs are widely used in applications that require position and attitude measurements. And with the production of low-cost IMUs, it has been possible to expand this use beyond military and high-cost applications, reaching consumer devices such as cell phones, wearable technologies, physical exercise and rehabilitation equipment. But every IMU needs to be calibrated for use and therefore, in addition to the sensor, there is the cost of calibration. Existing calibration methods are either proprietary to the manufacturers, or they are expensive and require specific equipment and laboratories, or they use non-optimal methods of parameter estimation. This work proposes the systematization of low cost calibration methods, with simple execution performed by the user and that provides optimized results closer to those achieved by high cost calibration methods. The data capture process is based on a multi-position method that does not require extra equipment, besides the sensor and computer itself. The experiments were executed with three commercial IMUs, one high-cost calibrated by the manufacturer, used as a reference, and two low-cost, uncalibrated. The raw accelerometer reading of each IMU was calibrated using the four forms of the Kalman filter developed in this work and the errors obtained were evaluated by comparing the high cost IMU and the calibration with the estimated parameters, showing the good performance of the methods.
dc.languagepor
dc.publisherUniversidade Federal de São Carlos
dc.publisherUFSCar
dc.publisherPrograma de Pós-Graduação em Engenharia Elétrica - PPGEE
dc.publisherCâmpus São Carlos
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil
dc.subjectIMU
dc.subjectFiltro de Kalman
dc.subjectCalibração
dc.subjectKalman Filter
dc.subjectCalibration
dc.titleMétodo automático de calibração de IMU baseado no filtro de Kalman
dc.typeTesis


Este ítem pertenece a la siguiente institución