dc.contributorUniv Extremo Sul Catarinense
dc.contributorUniversidade Federal de São Paulo (UNIFESP)
dc.contributorUniv Fed Rio Grande do Sul
dc.creatorSilvestre, A. C.
dc.creatorMathia, G. B. de
dc.creatorFagundes, D. J. [UNIFESP]
dc.creatorMedeiros, L. R.
dc.creatorRosa, M. I.
dc.date.accessioned2016-01-24T14:17:30Z
dc.date.accessioned2022-10-07T21:00:22Z
dc.date.available2016-01-24T14:17:30Z
dc.date.available2022-10-07T21:00:22Z
dc.date.created2016-01-24T14:17:30Z
dc.date.issued2011-12-01
dc.identifierHernia. New York: Springer, v. 15, n. 6, p. 629-634, 2011.
dc.identifier1265-4906
dc.identifierhttp://repositorio.unifesp.br/handle/11600/34275
dc.identifier10.1007/s10029-011-0853-6
dc.identifierWOS:000297768000005
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4025935
dc.description.abstractOne of the current complications in inguinal repair is shrinkage following the use of mesh. the selected mesh material, heavyweight (HWM) mesh or lightweight (LWM) mesh, is associated with the frequency of shrinkage. the aim of this study was to investigate shrinkage of these two types of mesh in a controlled trial of male inguinal hernia repair.Thirty-two healthy men with primary unilateral inguinal hernias (Nyhus classification), who presented at So Jos, Hospital of CriciA(0)ma, Brazil, underwent the Lichtenstein procedure. in total, 16 polypropylene HWM (105 g/m(2)) and 16 partially absorbable LWM (28 g/m(2)) were implanted into randomly selected patients. On post-operative days 1, 30, 60 and 90, the area of the mesh was evaluated by digital radiography.The study randomized 32 patients and analyzed 30 patients-15 for each type of mesh. At baseline, there were no differences between groups. There were significant differences between the two meshes when comparing the total area initially and on postoperative day 90 (P = 0.001). the HWM had significantly less area initial area, as compared with 90 days postoperatively (P = 0.04).Shrinkage was significantly higher for HWM, although the difference was not large.
dc.languageeng
dc.publisherSpringer
dc.relationHernia
dc.rightshttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dc.rightsAcesso restrito
dc.subjectInguinal hernia
dc.subjectRandomized controlled trial
dc.subjectMesh
dc.titleShrinkage evaluation of heavyweight and lightweight polypropylene meshes in inguinal hernia repair: a randomized controlled trial
dc.typeArtigo


Este ítem pertenece a la siguiente institución