dc.contributorHosp Servidor Publ Estadual Sao Paulo Francisco M
dc.contributorUniversidade Federal de São Paulo (UNIFESP)
dc.creatorRau, Ricardo [UNIFESP]
dc.creatorSilva, André Luiz de Freitas [UNIFESP]
dc.creatorSalame, André Luiz Alves [UNIFESP]
dc.creatorMelo Junior, Luiz Alberto Soares [UNIFESP]
dc.date.accessioned2018-06-18T11:43:56Z
dc.date.accessioned2022-10-07T20:48:12Z
dc.date.available2018-06-18T11:43:56Z
dc.date.available2022-10-07T20:48:12Z
dc.date.created2018-06-18T11:43:56Z
dc.date.issued2012-09-01
dc.identifierRevista Brasileira De Oftalmologia. Rio De Janeiro: Soc Brasileira Oftalmologia, v. 71, n. 5, p. 280-284, 2012.
dc.identifier0034-7280
dc.identifierhttp://repositorio.unifesp.br/11600/45371
dc.identifierS0034-72802012000500002.pdf
dc.identifierS0034-72802012000500002
dc.identifier10.1590/S0034-72802012000500002
dc.identifierWOS:000310855200002
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4023101
dc.description.abstractPurpose: To determine the reproducibility of the peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with the optical coherence tomography (SD-OCT) in normal eyes. Methods: Thirty-four eyes of 34 healthy patients were included in the study. The Cirrus OCT optic disc cube 200x200 protocol was used to obtain three scans from each eye to evaluate the reproducibility. Intraclass correlation coefficient (ICC) was calculated for the measurements of retinal nerve fiber layer thickness and optic nerve head parameters. Results: The correlation was excellent for all measures of retinal nerve fiber layer thickness (ICC between 0.87 and 0.98). The same happened with the optic nerve head parameters (ranging from 0.83 to 0.99), with the exception of E/D vertical ratio (0.56). Conclusion: Measurements of peripappilary retinal nerve fiber layer thickness and optic nerve head parameters showed excellent reproducibility with Cirrus OCT, indicating that this instrument may be useful in the study of glaucoma. This study has some limitations, including the small number of cases studied, further studies are needed to corroborate our findings.
dc.languagepor
dc.publisherSoc Brasileira Oftalmologia
dc.relationRevista Brasileira De Oftalmologia
dc.rightsAcesso aberto
dc.subjectTomography, optical coherence
dc.subjectOptic nerve
dc.subjectGlaucoma
dc.subjectReproducibility of results
dc.subjectRetina
dc.titleAvaliação da reprodutibilidade das medidas da camada de fibras nervosas retiniana e da cabeça do nervo óptico pela tomografia de coerência óptica
dc.typeArtigo


Este ítem pertenece a la siguiente institución