dc.creatorSousa, Clarivaldo Santos de
dc.creatorKorn, Mauro
dc.creatorSousa, Clarivaldo Santos de
dc.creatorKorn, Mauro
dc.date.accessioned2022-10-07T15:59:13Z
dc.date.available2022-10-07T15:59:13Z
dc.date.issued2001
dc.identifier0003-2670
dc.identifierhttp://www.repositorio.ufba.br/ri/handle/ri/7625
dc.identifierv. 444, n. 2
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4006381
dc.description.abstractInfluence of ultrasonic waves in the spectrophotometric determination of nickel with dimethylglyoxime (DMG) was investigated and interferences from foreign species such as Co2+, Fe2+ and Cu2+ were studied. A 1.5-fold sensitivity enhancement in relation to the conventional method involving nickel oxidation with persulfate was attained. In addition, operator handling and reagent consumption were lessened. The analytical curve was linear from 0.15 to 1.5 mg l−1 Ni and detection limit was estimated as 13 μg l−1 Ni. The procedure was applied to the analysis of alloys, containing Co, Fe and Cu in different proportion, and accuracy was assessed by using certified reference materials.
dc.languageen
dc.sourcehttp://dx.doi.org/10.1016/S0003-2670(01)01207-7
dc.subjectUltrasonic waves
dc.subjectReagent generation
dc.subjectNickel determination
dc.subjectAlloys
dc.subjectSpectrophotometry
dc.titleEffects of ultrasonic irradiation on the spectrophotometric determination of nickel with dimethylglyoxime
dc.typeArtigo de Periódico


Este ítem pertenece a la siguiente institución