dc.creator | Santos, Walter Nei Lopes dos | |
dc.creator | Silva, Erik Galvão Paranhos da | |
dc.creator | Fernandes, Marcelo Santiago | |
dc.creator | Araujo, Rennan Geovanny Oliveira | |
dc.creator | Costa, Antonio Celso Spinola | |
dc.creator | Santos, Walter Nei Lopes dos | |
dc.creator | Silva, Erik Galvão Paranhos da | |
dc.creator | Fernandes, Marcelo Santiago | |
dc.creator | Araujo, Rennan Geovanny Oliveira | |
dc.creator | Costa, Antonio Celso Spinola | |
dc.date.accessioned | 2022-10-07T15:36:51Z | |
dc.date.available | 2022-10-07T15:36:51Z | |
dc.date.issued | 2005 | |
dc.identifier | 1618-2642 | |
dc.identifier | http://www.repositorio.ufba.br/ri/handle/ri/6480 | |
dc.identifier | v. 382, n. 4 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/4005408 | |
dc.description.abstract | Chocolate is a complex sample with a high
content of organic compounds and its analysis generally
involves digestion procedures that might include the risk
of losses and/or contamination. The determination of
copper in chocolate is important because copper compounds
are extensively used as fungicides in the farming
of cocoa. In this paper, a slurry-sampling flame atomicabsorption
spectrometric method is proposed for
determination of copper in powdered chocolate samples.
Optimization was carried out using univariate methodology
involving the variables nature and concentration
of the acid solution for slurry preparation, sonication
time, and sample mass. The recommended conditions
include a sample mass of 0.2 g, 2.0 mol L 1 hydrochloric
acid solution, and a sonication time of 15 min.
The calibration curve was prepared using aqueous copper
standards in 2.0 mol L 1 hydrochloric acid. This
method allowed determination of copper in chocolate
with a detection limit of 0.4 lg g 1 and precision, expressed
as relative standard deviation (RSD), of 2.5%
(n=10) for a copper content of approximately
30 lg g 1, using a chocolate mass of 0.2 g. The accuracy
was confirmed by analyzing the certified reference
materials NIST SRM 1568a rice flour and NIES CRM
10-b rice flour. The proposed method was used for
determination of copper in three powdered chocolate
samples, the copper content of which varied between
26.6 and 31.5 lg g 1. The results showed no significant differences with those obtained after complete digestion,
using a t-test for comparison. | |
dc.language | en | |
dc.publisher | Springer Verlag | |
dc.source | http://www.springerlink.com/content/n86182457l465jv6/fulltext.pdf | |
dc.subject | slurry-sampling | |
dc.subject | FAAS | |
dc.subject | Copper | |
dc.subject | Chocolate | |
dc.title | Determination of copper in powdered chocolate samples by slurry-sampling flame atomic-absorption spectrometry | |
dc.type | Artigo de Periódico | |