Brasil
| masterThesis
Utilização do transistor bipolar de junção para medição da uniformidade do campo de radiação em mamografia
dc.contributor | SANTOS, Luiz Antonio Pereira dos | |
dc.contributor | http://lattes.cnpq.br/1924500666045929 | |
dc.contributor | http://lattes.cnpq.br/1168675569547602 | |
dc.creator | SILVA FILHO, José Fernando da | |
dc.date | 2019-04-25T21:30:45Z | |
dc.date | 2019-04-25T21:30:45Z | |
dc.date | 2018-02-06 | |
dc.date.accessioned | 2022-10-06T18:50:56Z | |
dc.date.available | 2022-10-06T18:50:56Z | |
dc.identifier | https://repositorio.ufpe.br/handle/123456789/30326 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/3991732 | |
dc.description | A mamografia é uma técnica de raios X de diagnóstico por imagem muito importante para antecipar o diagnóstico do câncer de mama e reduzir consideravelmente as chances de morte em quase 95% dos pacientes, quando a doença é descoberta em seu estágio inicial. Na verdade, tal exame radiográfico pode alcançar o sucesso se o resultado da imagem for de alta qualidade. No equipamento de mamografia existem vários parâmetros que desempenham um papel importante na qualidade da imagem radiográfica. Um dos parâmetros é a uniformidade do campo de radiação. Entre os vários testes de controle de qualidade em mamografia, ainda não existe uma metodologia de eletrônica fina (como uma tecnologia de instrumentação nuclear) para medições da uniformidade do campo de radiação. Nesse sentido, o objetivo deste trabalho foi estudar a viabilidade do transistor bipolar de junção como um sensor de radiação para medir a uniformidade do campo de radiação em feixes de raios X de mamografia. A resposta do transistor foi comparada com o detector padrão (a câmara de ionização), e os resultados mostram que o transistor bipolar de junção pode ser utilizado como um sensor de radiação para medir a uniformidade do campo de radiação. | |
dc.description | Mammography is a very important imaging diagnostic X-ray technique to anticipate the diagnosis of breast cancer and reduce the chances of death in almost 95% of patients if the disease is discovered in its early stages. In fact, such a radiographic examination can achieve success if the result of the image has high quality. In mammography equipment there are several parameters that play an important role in the quality of the radiographic image. One of the parameters is the uniformity of the radiation field. Among the various quality control tests in mammography, there is still no fine electronics methodology (as a nuclear instrumentation technology) for measurements of the radiation field uniformity. In this sense, the objective of this work was to study the viability of the bipolar junction transistor as a radiation sensor for measuring the uniformity of the radiation field in mammography X-ray beams. The transistor response was compared with the standard detector (the ionization chamber), and the results show that the bipolar junction transistor could be used as a radiation sensor for measuring the uniformity of the radiation field. | |
dc.format | application/pdf | |
dc.language | por | |
dc.publisher | Universidade Federal de Pernambuco | |
dc.publisher | UFPE | |
dc.publisher | Brasil | |
dc.publisher | Programa de Pos Graduacao em Tecnologias Energeticas e Nuclear | |
dc.rights | openAccess | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | |
dc.subject | Mamografia | |
dc.subject | Uniformidade do campo de radiação | |
dc.subject | Transistor bipolar de junção | |
dc.title | Utilização do transistor bipolar de junção para medição da uniformidade do campo de radiação em mamografia | |
dc.type | masterThesis |