dc.contributorGermano, Adriano Rocha
dc.contributor
dc.contributor
dc.contributorSoares, Eduardo Costa Studart
dc.contributor
dc.contributorNoleto Júnior, José Wilson
dc.contributor
dc.creatorSilveira, Marcelo Leite Machado da
dc.date.accessioned2019-04-08T21:08:14Z
dc.date.accessioned2022-10-06T14:10:57Z
dc.date.available2019-04-08T21:08:14Z
dc.date.available2022-10-06T14:10:57Z
dc.date.created2019-04-08T21:08:14Z
dc.date.issued2018-08-10
dc.identifierSILVEIRA, Marcelo Leite Machado da. Análise biomecânica de diferentes tipos de fixação em osteotomia sagital do ramo após diferentes avanços e alterações do plano mandibular: um estudo com elementos finitos. 2018. 74f. Dissertação (Mestrado em Saúde Coletiva) - Centro de Ciências da Saúde, Universidade Federal do Rio Grande do Norte, Natal, 2018.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/26884
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3975446
dc.description.abstractThe aim of the present paper was to evaluate, via a finite element analysis, the tensions on the cortical bone and the plating system, as to evaluate mandibular resistance after the sagittal split ramus osteotomy with different mandibular advancements and mandibular plane movements. 3D mandibular models were obtained and a 6mm and 12mm advancement was planned associated with linear, clockwise or counter clockwise rotation of the mandibular plane angle. Each model was then fixed with one or two plates of the 2.0mm system and held with 4 monocortical screws at each side. A total of 12 models were built and they were subjected to a vertical load in the incisors region ranging from 50N to 500N in 50N increments. Results have shown that the 12mm advancement was associated with a higher tension in the cortical bone and plate surface. It was also concluded that the models fixed with 2 plates presented lower values of tension on the plates in comparison with the models fixed with a single plate. Counter clockwise rotation of the mandibular plane angle in the 6mm advancement, fixed with 1 or 2 plates, brought more tension to the plates, which did not occur in the 12mm advancements. These results may aid surgeons with decision making on a daily basis.
dc.publisherBrasil
dc.publisherUFRN
dc.publisherPROGRAMA DE PÓS-GRADUAÇÃO EM SAÚDE COLETIVA
dc.rightsAcesso Aberto
dc.subjectOsteotomia sagital do ramo mandibular
dc.subjectRotação no sentido horário
dc.subjectFixação interna rígida
dc.subjectAnálise de elementos finitos
dc.titleAnálise biomecânica de diferentes tipos de fixação em osteotomia sagital do ramo após diferentes avanços e alterações do plano mandibular: um estudo com elementos finitos
dc.typemasterThesis


Este ítem pertenece a la siguiente institución