bachelorThesis
Sobrevida de sobredentaduras mandibulares implantorretidas pelo sistema barra-clipe
Survival of mandibular overdenture implant-retained by the system bar-clip
Registro en:
2011034996
SILVA, Cleice Luizi da. Sobrevida de sobredentaduras mandibulares implantorretidas pelo sistema barra-clipe. 2015. 8 f. Monografia (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2015.
Autor
Silva, Cleice Luizi da
Resumen
This study aimed to evaluate fractures that attacked mandibular overdentures retained by two
implants with bar clip system and correlates them with the existing mandibular space,
thickness of the prosthesis and masticatory efficiency. This is a retrospective cohort study
with a sample of 23 patients toothless bimaxillary users double conventional dentures which
had their lower dentures converted to removable dentures on implants - overdentures. All
patients were rehabilitated in Clinical Prosthodontics and Maxillofacial Surgery Department
of Dentistry (DOD) in the Federal University of Rio Grande do Norte (UFRN) from January
2011 to April 2014. The mandibular space was measured with the aid of a millimeter ruler
and needle point. The thickness of the base of the overdenture was checked with use of a
manual espessímetro at a specific point. Masticatory efficiencies were collected from a
database of a previous search that used the colorimetric method with fuscina capsule. Survival
analysis of Kaplan-Meier and the T test to analyze the independent variables was used. There
were eight fractures which represents a total of 34.7% of the sample. The found survival rate
was 49.5% and were not found significant values (p <0.05) variables related to occurrence of
fracture (mandibular space, thickness of the denture base and masticatory efficiency). It was
concluded that it is technically difficult to prevent such an occurrence, so it is suggested
strengthening the prosthesis structure as part of the protocol in its manufacturing process. This study aimed to evaluate fractures that attacked mandibular overdentures retained by two
implants with bar clip system and correlates them with the existing mandibular space,
thickness of the prosthesis and masticatory efficiency. This is a retrospective cohort study
with a sample of 23 patients toothless bimaxillary users double conventional dentures which
had their lower dentures converted to removable dentures on implants - overdentures. All
patients were rehabilitated in Clinical Prosthodontics and Maxillofacial Surgery Department
of Dentistry (DOD) in the Federal University of Rio Grande do Norte (UFRN) from January
2011 to April 2014. The mandibular space was measured with the aid of a millimeter ruler
and needle point. The thickness of the base of the overdenture was checked with use of a
manual espessímetro at a specific point. Masticatory efficiencies were collected from a
database of a previous search that used the colorimetric method with fuscina capsule. Survival
analysis of Kaplan-Meier and the T test to analyze the independent variables was used. There
were eight fractures which represents a total of 34.7% of the sample. The found survival rate
was 49.5% and were not found significant values (p <0.05) variables related to occurrence of
fracture (mandibular space, thickness of the denture base and masticatory efficiency). It was
concluded that it is technically difficult to prevent such an occurrence, so it is suggested
strengthening the prosthesis structure as part of the protocol in its manufacturing process.