dc.contributorLima, Kássio Michell Gomes de
dc.contributorMedeiros, Maria de Fátima Dantas de
dc.contributorCosta, Fernanda Saadna Lopes da
dc.creatorAndrade, Eduardo Wagner Vasconcelos de
dc.date.accessioned2017-11-17T16:28:06Z
dc.date.accessioned2021-09-27T12:19:15Z
dc.date.accessioned2022-10-06T13:39:46Z
dc.date.available2017-11-17T16:28:06Z
dc.date.available2021-09-27T12:19:15Z
dc.date.available2022-10-06T13:39:46Z
dc.date.created2017-11-17T16:28:06Z
dc.date.created2021-09-27T12:19:15Z
dc.date.issued2017-11-03
dc.identifierANDRADE, Eduardo Wagner Vasconcelos de. Transferência de cartas de controle multivariada empregando espectrômetros NIR para determinação simultânea de rifampicina e isoniazida numa formulação farmacêutica. 2017. 77f. Trabalho de Conclusão de Curso (Graduação em Engenharia Química), Departamento de Engenharia Química, Universidade Federal do Rio Grande do Norte, Natal, 2017.
dc.identifierhttps://repositorio.ufrn.br/handle/123456789/38705
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3971749
dc.description.abstractThis study reports a new multivariate control chart transfer approach between two near infrared (NIR) spectrometers for simultaneous determination of rifampicin and isoniazid in pharmaceutical formulation using direct standardization (DS). The control charts are based on the calculation of net analyte signal (NAS) models and the transfer samples are selected by the Kennard-Stone (KS) algorithm. Three control (NAS, interference and residual) charts transfer on both the master and slave instruments were measured. As a result, a classification model for rifampicin and isoniazid developed on a primary instrument has been successfully transferred to a secondary instrument. The spectral differences after the standardization procedure reduced considerably and errors values found in the charts for both analytes were comparable with the errors obtained for the original chart models. The proposed approach appears to be a valid alternative to the commonly used transfer of multivariate calibration models.
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBrasil
dc.publisherUFRN
dc.publisherEngenharia Química
dc.rightsopenAccess
dc.subjectTransferência de cartas de controle multivariadas
dc.subjectSinal analítico líquido
dc.subjectIsoniazida
dc.subjectRifampicina
dc.subjectPadronização direta
dc.subjectNIR
dc.titleTransferência de cartas de controle multivariada empregando espectrômetros NIR para determinação simultânea de rifampicina e isoniazida numa formulação farmacêutica
dc.typebachelorThesis


Este ítem pertenece a la siguiente institución