dc.contributor | Deus, Katherine Carrilho de Oliveira | |
dc.contributor | Dantas, Tereza Neuma de Castro | |
dc.contributor | Oliveira, Humberto Neves Maia de | |
dc.contributor | Oliveira, Humberto | |
dc.creator | Lima, Daniel Godoy | |
dc.date.accessioned | 2022-07-27T15:09:41Z | |
dc.date.accessioned | 2022-10-06T13:05:38Z | |
dc.date.available | 2022-07-27T15:09:41Z | |
dc.date.available | 2022-10-06T13:05:38Z | |
dc.date.created | 2022-07-27T15:09:41Z | |
dc.date.issued | 2022-07-06 | |
dc.identifier | LIMA, Daniel Godoy. Estudo de extração líquido- líquido aplicado a um extrator de pratos recíprocos. 2022. 107f. Trabalho de Conclusão de Curso (Graduação em Engenharia Química) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2022. | |
dc.identifier | https://repositorio.ufrn.br/handle/123456789/48771 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/3963740 | |
dc.description.abstract | Liquid-liquid extraction is an important industrial operation aimed at separating or purifying
a system. It is an operation that can be used for the treatment of aqueous effluents originated
during the extraction of oil. In this work, the objective was to assemble and study the liquidliquid extraction operation in a column of reciprocal perforated plates to obtain operational
data from the equipment. The system applied was Toluene – Water – Acetone as a way to
validate the extraction column on a pilot scale based on existing data in the literature. Allied
to this, a study of mass transfer in droplets was carried out in the same system, by analyzing
data obtained from the Krüss® Drop Shape DSA100 tensiometer – interfacial tension and
drop diameter. In the studies of axial dispersion in the column, the experimental Peclet
number found was approximately 8.15 and the dispersion coefficient (E) was equal to 82.21
cm²/s. For the Toluene – Water – Acetone system, which was operated in emulsion in the
extractor, an extraction efficiency of 87.27% was found. The global coefficients of mass
transfer presented in the study of drop analysis, regardless of the direction of mass transport,
values equal to 0.00012 (m/s) - consistent with the data found in the literature. | |
dc.publisher | Universidade Federal do Rio Grande do Norte | |
dc.publisher | Brasil | |
dc.publisher | UFRN | |
dc.publisher | Engenharia Química | |
dc.publisher | Departamento de Engenharia Química | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | |
dc.subject | Extração líquido-líquido | |
dc.subject | Transferência de massa | |
dc.subject | Tensão interfacial | |
dc.subject | Extrator de pratos perfurados recíprocos | |
dc.subject | Liquid-liquid extraction | |
dc.subject | Mass transference | |
dc.subject | Interfacial tension and reciprocal perforated plates extractor | |
dc.title | Estudo de extração líquido- líquido aplicado a um extrator de pratos recíprocos | |
dc.type | bachelorThesis | |