dc.contributorCalderon, Patrícia dos Santos
dc.contributor
dc.contributorhttp://lattes.cnpq.br/1817241533654813
dc.contributor
dc.contributorhttp://lattes.cnpq.br/7722422585349321
dc.contributorCarreiro, Adriana da Fonte Porto
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6618350120004415
dc.contributorBatista, André Ulisses Dantas
dc.contributor
dc.contributorhttp://lattes.cnpq.br/9510942902249475
dc.creatorDantas, Poliana Medeiros Cunha
dc.date.accessioned2013-10-16
dc.date.accessioned2014-12-17T15:43:52Z
dc.date.accessioned2022-10-06T12:38:25Z
dc.date.available2013-10-16
dc.date.available2014-12-17T15:43:52Z
dc.date.available2022-10-06T12:38:25Z
dc.date.created2013-10-16
dc.date.created2014-12-17T15:43:52Z
dc.date.issued2012-12-13
dc.identifierDANTAS, Poliana Medeiros Cunha. Avaliação clínica e radiográfica das complicações técnicas em próteses sobre implantes. 2012. 64 f. Dissertação (Mestrado em Saúde Pública) - Universidade Federal do Rio Grande do Norte, Natal, 2012.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/17823
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3956275
dc.description.abstractThe evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBR
dc.publisherUFRN
dc.publisherPrograma de Pós-Graduação em Saúde Coletiva
dc.publisherSaúde Pública
dc.rightsAcesso Aberto
dc.subjectImplante dentário. Prótese dentária fixada por implante. Análise de sobrevida. Falha de Tratamento. Radiografia
dc.subjectDental implant. Dental prosthesis implant-supported. Survival Analysis. Treatment failure. Radiograph
dc.titleAvaliação clínica e radiográfica das complicações técnicas em próteses sobre implantes
dc.typemasterThesis


Este ítem pertenece a la siguiente institución