Avaliação de metodologia de preparo de amostra de petróleo por digestão ácida auxiliada por microondas para determinação de metais por ICP-OES

dc.contributorSilva, Djalma Ribeiro da
dc.contributor
dc.contributor
dc.contributorhttp://lattes.cnpq.br/2791074318745945
dc.contributorMoura, Maria de Fátima Vitória de
dc.contributor
dc.contributorhttp://lattes.cnpq.br/2959800336802498
dc.contributorBarbosa, Andréa Francisca Fernandes
dc.contributor
dc.contributorMaranhão, Tatiane de Andrade
dc.contributor
dc.contributorhttp://lattes.cnpq.br/2283703059305052
dc.creatorSilva, Izabel Kaline Vicente da
dc.date.accessioned2013-05-15
dc.date.accessioned2014-12-17T14:08:52Z
dc.date.accessioned2022-10-06T12:20:08Z
dc.date.available2013-05-15
dc.date.available2014-12-17T14:08:52Z
dc.date.available2022-10-06T12:20:08Z
dc.date.created2013-05-15
dc.date.created2014-12-17T14:08:52Z
dc.date.issued2012-12-14
dc.identifierSILVA, Izabel Kaline Vicente da. Avaliação de metodologia de preparo de amostra de petróleo por digestão ácida auxiliada por microondas para determinação de metais por ICP-OES. 2012. 62 f. Dissertação (Mestrado em Pesquisa e Desenvolvimento em Ciência e Engenharia de Petróleo) - Universidade Federal do Rio Grande do Norte, Natal, 2012.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/12979
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3950267
dc.description.abstractThis project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBR
dc.publisherUFRN
dc.publisherPrograma de Pós-Graduação em Ciência e Engenharia do Petróleo
dc.publisherPesquisa e Desenvolvimento em Ciência e Engenharia de Petróleo
dc.rightsAcesso Aberto
dc.subjectDigestão ácida. Box Behnken. Metais. Petróleo e ICP-OES
dc.subjectAcid digestion. Box Behnken. Metals. Oil and ICP-OES
dc.titleAvaliação de metodologia de preparo de amostra de petróleo por digestão ácida auxiliada por microondas para determinação de metais por ICP-OES
dc.titleAvaliação de metodologia de preparo de amostra de petróleo por digestão ácida auxiliada por microondas para determinação de metais por ICP-OES
dc.typemasterThesis


Este ítem pertenece a la siguiente institución