dc.identifierSOUZA, Flávia Beatriz Cavalcante. Utilização da metodologia HFMEA para identificação de padrões de falhas em equipamento do parque tecnológico da Maternidade Escola Januário Cicco. Orientador: Custódio Leopoldino de Brito. 2022. 46f. Trabalho de Conclusão de Curso (Graduação em Engenharia Biomédica) - Departamento de Engenharia Biomédica, Universidade Federal do Rio Grande do Norte, Natal, 2022.
dc.identifierhttps://repositorio.ufrn.br/handle/123456789/49367
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3945487
dc.description.abstractA major purpose in the medical field, specifically in the part of hospital-medical equipment management area, is the identification and prevention of potential failures. The health and safety of patients are primary focus area, which is why preventing errors and possible failures in medical equipment is so important. Currently, tools such as Failure Mode and Effects Analysis (FMEA) are applied to healthcare as a proactive risk maintenance solution. It works by identifying the modes, causing the failures, and causing the activation of the most important solutions and eliminating the risks. Thus, we present a study on the use of an FMEA tool applied to health (HFMEA) to investigate failures in equipment in the technology park. Therefore, a bibliographic review of the HFMEA was carried out, which served as a basis for the application of the tool in the clinical sector of the Januário Cicco Maternity School. Create a spreadsheet to do analysis, point of failure and risk assessment. The study of the membrane of the exhalation valve that is part of the internal circuit of the pulmonary ventilator was carried out. Potential valve membrane failures were identified using the method in question. It is concluded that the HFMEA methodology is efficient and extremely necessary to detect failures in health equipment.
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBrasil
dc.publisherUFRN
dc.publisherEngenharia Biomédica
dc.publisherEngenharia Biomédica
dc.rightshttp://creativecommons.org/licenses/by-nd/3.0/br/
dc.rightsAttribution-NoDerivs 3.0 Brazil
dc.subjectFMEA
dc.subjectEquipamento médico
dc.subjectHFMEA
dc.subjectOtimização de equipamentos
dc.subjectAnálise de risco à saúde
dc.subjectMedical equipment
dc.subjectEquipment optimization
dc.subjectHealthcare risk analysis
dc.titleUtilização da metodologia HFMEA para identificação de padrões de falhas em equipamento do parque tecnológico da Maternidade Escola Januário Cicco