dc.contributorCarreiro, Adriana da Fonte Porto
dc.contributor
dc.contributorhttp://lattes.cnpq.br/4381290763159361
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6618350120004415
dc.contributorSeabra, Eduardo José Guerra
dc.contributor
dc.contributorhttp://lattes.cnpq.br/2882454174218035
dc.contributorCalderon, Patrícia dos Santos
dc.contributor
dc.contributorhttp://lattes.cnpq.br/7722422585349321
dc.creatorTôrres, Ana Clara Soares Paiva
dc.date.accessioned2014-11-24
dc.date.accessioned2014-12-17T15:43:56Z
dc.date.accessioned2022-10-05T23:02:47Z
dc.date.available2014-11-24
dc.date.available2014-12-17T15:43:56Z
dc.date.available2022-10-05T23:02:47Z
dc.date.created2014-11-24
dc.date.created2014-12-17T15:43:56Z
dc.date.issued2014-03-11
dc.identifierTÔRRES, Ana Clara Soares Paiva. Falhas e complicações com o uso de prótese parcial removível inferior de extremidade livre bilateral. 2014. 69 f. Dissertação (Mestrado em Saúde Pública) - Universidade Federal do Rio Grande do Norte, Natal, 2014.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/17848
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3945337
dc.description.abstractAim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBR
dc.publisherUFRN
dc.publisherPrograma de Pós-Graduação em Saúde Coletiva
dc.publisherSaúde Pública
dc.rightsAcesso Aberto
dc.subjectPrótese Parcial Removível. Arcada parcialmente edentada. Mandíbula e Complicações
dc.subjectRemovable partial denture. Partially edentulous arch. Mandible and Complications
dc.titleFalhas e complicações com o uso de prótese parcial removível inferior de extremidade livre bilateral
dc.typemasterThesis


Este ítem pertenece a la siguiente institución