dc.creatorAraújo, Paulo Victor do Nascimento
dc.creatorAmaro, Venerando Eustáquio
dc.creatorAlcoforado, Alex Vinícius Capistrano
dc.creatorSantos, André Luis Silva dos
dc.date.accessioned2020-12-08T14:10:29Z
dc.date.accessioned2022-10-05T22:59:42Z
dc.date.available2020-12-08T14:10:29Z
dc.date.available2022-10-05T22:59:42Z
dc.date.created2020-12-08T14:10:29Z
dc.date.issued2018
dc.identifierARAÚJO, P.V.N. ; AMARO, V.E. ; ALCOFORADO, A.V.C. ; SANTOS, A.L.S. . Vertical Accuracy and Calibration of Digital Elevation Models (DEMs) for the Piranhas-Assu River Basin, Rio Grande do Norte, Brazil. Auário do Instituto de Geociências (UFRJ. IMPRESSO), v. 41, p. 351-364, 2018. Disponível em: https://revistas.ufrj.br/index.php/aigeo/article/view/27784. Acesso em: 26 nov. 2020. https://doi.org/10.11137/2018_1_351_364
dc.identifierhttps://repositorio.ufrn.br/handle/123456789/30906
dc.identifier10.11137/2018_1_351_364
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3943956
dc.description.abstractThere is a growing need for high resolution altimetry data to use in environmental research in the last years. Therefore, addition criteria must be applied for this data usage, especially due to vertical error. This paper focuses on vertical error evaluation and calibration methodology of Digital Elevation Models (DEM) obtained with Shuttle Radar Topographic Mission and with airborne Light Detection and Ranging in the Piranhas-Açu river basin; north part of Rio Grande do Norte State, Brazil. The evaluation and calibration was conducted in two sectors of the study area: regional and local. The regional sector was evaluated with SRTM data only and the local sector with DEM from SRTM and airborne LiDAR. The calibration used a network of high vertical accuracy altimetric control points data. The results show that the in the study area the SRTM DEM accuracy is satisfactory and was improved by 26-29% after calibration. In the local area, airborne LiDAR is more accurate than SRTM and was also enhanced by control points calibration (15%). This paper demonstrates the need for vertical error analysis and calibration in DEM prior to topographic use
dc.publisherAnuário do Instituto de Geociências
dc.rightshttp://creativecommons.org/licenses/by/3.0/br/
dc.rightsAttribution 3.0 Brazil
dc.subjectAltimetria
dc.subjectGNSS
dc.subjectSRTM
dc.subjectLiDAR Aerotransportado
dc.titleAcurácia vertical e calibração de modelos digitais de elevação (MDEs) para a bacia hidrográfica Piranhas-Açú, Rio Grande do Norte, Brasil
dc.typearticle


Este ítem pertenece a la siguiente institución