Artigo
Poly [1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II)] solutions used as low dose ionizing radiation dosimeter
Fecha
2013-06-17Registro en:
Applied Physics Letters, v. 102, n. 24, 2013.
0003-6951
10.1063/1.4812186
WOS:000320962400038
2-s2.0-84879804274
2-s2.0-84879804274.pdf
0000-0003-0162-8273
Autor
Universidade Estadual Paulista (Unesp)
University of Rome Sapienza
Resumen
In this work, the effect of gamma radiation on the optical properties of polymetallayne poly[1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II) ] (Pt-DEBP) in chloroform solution is studied. The samples were irradiated at room temperature with doses from 0.01 Gy to 1 Gy using a 60Co gamma ray source. A new band at 420 nm is observed in the emission spectra, in superposition to the emission maximum at 398 nm, linearly dependent on dose. We propose to use the ratio of the emission amplitude bands as the dosimetric parameter. This method proved to be robust, accurate, and can be used as a dosimeter in medical applications. © 2013 AIP Publishing LLC.