dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:25:28Z
dc.date.accessioned2022-10-05T18:25:53Z
dc.date.available2014-05-27T11:25:28Z
dc.date.available2022-10-05T18:25:53Z
dc.date.created2014-05-27T11:25:28Z
dc.date.issued2011-02-01
dc.identifierControle y Automacao, v. 22, n. 1, p. 23-38, 2011.
dc.identifier0103-1759
dc.identifierhttp://hdl.handle.net/11449/72303
dc.identifier10.1590/S0103-17592011000100003
dc.identifierS0103-17592011000100003
dc.identifier2-s2.0-79953312647
dc.identifier2-s2.0-79953312647.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3921381
dc.description.abstractMultipulse rectifier topologies based on auto-connections or differential connections, are more and more applied as interface stages between the mains and power converters. These topologies are becoming increasingly attractive not only for robustness, but to mitigate many low order current harmonics in the utility, reducing the total harmonic distortion of the line currents (THDi) and increasing the power factor requirements. Unlike isolated connections (delta-wye, zigzag, etc.), when the differential transformer is employed, most of the energy required by the load is directly conducted through the windings. Thus, only a small fraction of the kVA is processed by the magnetic core. This feature increases the power density of the converter. This paper presents a mathematical model based on phasor diagrams, which results in a single expression able to merge all differential connections (wye and delta), for both step-up and step-down rectifiers for 12 or 18 pulses. The proposed family of converters can be designed for any relationship between the line input voltage and the DC voltage, unlike the conventional phase-shift voltage connections. An immediate application would be the retrofit, i.e. to replace a conventional rectifier with poor quality of the processed energy by the 12 or 18-pulse rectifiers with Wye or Delta-differential connections, keeping the original values for the input and load voltages. The simple and fast design procedure is developed and tested for a prototype rating 6 kW and 400 V on DC load.
dc.languagepor
dc.relationControle y Automacao
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectAutotransformer
dc.subjectDifferential connection
dc.subjectMultipulse
dc.subjectPower factor correction
dc.subjectThree-phase rectifier
dc.subjectMultipulses
dc.subjectThree-phase rectifiers
dc.subjectDC power transmission
dc.subjectElectric power factor correction
dc.subjectMagnetic circuits
dc.subjectMathematical models
dc.subjectRectifying circuits
dc.subjectRetrofitting
dc.subjectTopology
dc.subjectTransformer windings
dc.subjectElectric rectifiers
dc.titleFamília de retificadores multipulsos com topologias diferenciais de transformadores
dc.typeArtigo


Este ítem pertenece a la siguiente institución